11 Supplement
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Cable gland
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Display and adjustment module
Display element
Measured value indication
Ʋ Number of digits
Ʋ Size of digits
Adjustment elements
Protection rating
Ʋ unassembled
Ʋ mounted in the housing without lid
Materials
Ʋ Housing
Ʋ Inspection window
Integrated clock
Date format
Time format
Time zone Ex factory
Rate deviation max.
Measurement electronics temerature
Resolution
Accuracy
Permissible temperature range
Voltage supply
Operating voltage U
Ʋ Non-Ex instrument
Ʋ Ex-ia instrument
Operating voltage U
Ʋ Non-Ex instrument
Ʋ Ex-ia instrument
Reverse voltage protection
Permissible residual ripple - Non-Ex, Ex-ia instrument
Ʋ for 9.6 V< U
< 14 V
B
Ʋ for 18 V< U
< 36 V
B
62
B
- illuminated display and adjustment module
B
LEVEL TRANSMITTER 8136 • 4 ... 20 mA/HART - two-wire
M20 x 1.5 or ½ NPT
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
Display with backlight
5
W x H = 7 x 13 mm
4 keys
IP 20
IP 40
ABS
Polyester foil
Day.Month.Year
12 h/24 h
CET
10.5 min/year
0.1 °C (1.8 °F)
±1 °C (1.8 °F)
-40 ... +85 °C (-40 ... +185 °F)
9.6 ... 36 V DC
9.6 ... 30 V DC
16 ... 36 V DC
16 ... 30 V DC
Integrated
≤ 0.7 V
(16 ... 400 Hz)
eff
≤ 1.0 V
(16 ... 400 Hz)
eff