Télécharger Imprimer la page

Burkert 8136 Mode D'emploi page 37

Publicité

Les langues disponibles

Les langues disponibles

6 Set up with the display and adjustment module
36
certain circumstances only the medium with the higher dielectric
constant. Keep in mind that layer interfaces can cause faulty meas-
urements.
If you want to measure the total height of both liquids reliably, please
contact our service department or use an instrument specially de-
signed for interface measurement.
The following options are available when "Bulk solid" is selected:
The following features form the basis of the applications:
Silo (slender and high):
Vessel of metal: weld joints
Process/measurement conditions:
– Filling aperture too close to the sensor
– System noise in completely empty silo increased
Properties, sensor:
– Stable measured values through higher averaging
– False signal suppression during setup recommended, required
for automatic false signal suppression
– Automatic false signal suppression with partly filled vessel
Bunker (large-volume):
Vessel of concrete or metal:
– Structured vessel walls
– Installations present
Process/measurement conditions:
– Large distance to the medium
– Large angles of repose
Properties, sensor:
– Mean averaging
– High measured value jumps are accepted
Bunker with fast filling:
Vessel of concrete or metal, also multiple chamber silo:
– Structured vessel walls
– Installations present
Process/measurement conditions:
– Measured value jumps, e.g. through truck loading
– Large distance to the medium
– Large angles of repose
Properties, sensor:
– Lower averaging
– Very high measured value jumps are accepted
Heap:
Sensor mounting on movable conveyor belts
Detection of the heap profile
Height detection during filling
LEVEL TRANSMITTER 8136 • 4 ... 20 mA/HART - two-wire

Publicité

loading