Télécharger Imprimer la page

Electric Connections - Rizzoli L Série Manuel D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

WARNING! For the correct working of the device verify that the passage of comburent
air is not obstructed or, in case of connection with external air intake, that the air aspira-
tion grill is not obstructed.
2.12

ELECTRIC CONNECTIONS

The electric connection of the cookers and ther-
mal cookers allows the lighting of the oven lamp.
The connection to AC power must be done by ex-
perienced people and according with existing laws.
The installer is responsible of the correct connec-
tion according with safety rules. To make the con-
nection, you have to connect an electric cable to
Picture 13 - Position of the terminal board for the connection to the network.
Picture 14 - Terminal board for the connection to the network: 1. Line 2. Neutral 3. Earth
L 90
1
2
3
the terminal board placed in the rear side of the
cooker. Must be done the correct connections of
line, neutral and earth as described in picture 14.
The cable and every other electric device added
must be dimensioned for the electric load to sus-
tain and must not be in contact with points 50° C
hotter than ambient temperature.
LT 90
83

Publicité

Chapitres

loading

Ce manuel est également adapté pour:

Lt sérieL 90Lt 90