2.15

ELECTRIC CONNECTIONS

The electric connection of the cookers allows the
working of the fans placed on the sides and the
lighting of the oven lamp for the models with oven.
The connection to AC power must be done by ex-
perienced people and according with existing laws.
The installer is responsible of the correct connec-
tion according with safety rules. To make the con-
nection, you have to connect an electric cable to
COOKER WITHOUT OVEN
Picture 18 - Position of the terminal board for the connection to the network.
Picture 19 - Terminal board for the connection to the network: 1. Line 2. Neutral 3. Earth.
1
2
3
112
the terminal board placed in the rear side of the
cooker. Must be done the correct connections of
line, neutral and earth as described in the picture.
The cable and every other electric device added
must be dimensioned for the electric load to sus-
tain and must not be in contact with points 50° C
hotter than ambient temperature.
COOKER WITH OVEN