English
2.4.4.2 Standard Operating Sequence
This item reflects a typical operating sequence of a crane scale:
Action
1. DISOMAT B plus must
be in home position!
Set display type: 'NET'
2.Hook on ropes or cross-
members, acquire tare.
3. Pick up load.
4.If need be, enter weight of
packaging or shopping
pallets as manual tare
value, or select value from
list of Fixed Tare values.
Not necessary if item 2 has
been performed.
5. If need be, enter string.
6. Weigh and print.
7. Totally relieve scale.
8. Clear tare memory.
BV-H2322 AA
0630
- 52 -
Display (e.g.)
Key; Comments
G
0.0 kg
If scale display does not read zero:
->'Zero Scale' key
G
103.5 kg
Net T
0.0 kg
Scale is tared
Net T 205.0 kg
Scale shows NET weight.
'Manual Tare Input' key or 'Fixed
do.
Tare' selection
Acquire input with key
do.
'Enter String' key
do.
do.
Print or store weigh data. Relieve
crane to perform next weighing
operation.
G 308.5 kg
Weighing is complete. Remove load
from scale, and scale is ready for
next weighing operation.
DISOMAT
© Schenck Process GmbH, Darmstadt
Scale Specific Control
'Acquire Tare' key
or
+
®
Opus – Operating Instructions