Action
4. If required, stop filling.
5. If required, abort filling.
6. Terminate filling.
7. Discharge hopper
Alternatively, you can also
perform a mere GROSS weighing. This function is used, if a hopper
containing a residual amount of material is to be filled. In this case, the taring
operation before filling is omitted.

2.4.2.3 Operating Activities

There are three types of printout and one print repeat function. For information on
formatting, see manual BV-H2313, Item 5.2.1.
Single Printout
After every fill operation, aborted or completed, system automatically performs a
single printout (weighing report). For single printout, DISOMAT uses form format 2.
Totals Printout
After one (or multiple) weighing operations, you can print total by pressing
[SHIFT]+[F3] (function key F6). System outputs the cumulative weight value of all fill
operations. Then, totals value (balance) is cleared, i.e. the totals weight of all weighing
operations performed and the number of fill operations are set to zero. For totals
printout, DISOMAT uses form format 3.
Sub-Totals Printout
[SHIFT]+[F1] (function key F4) lets you print current balance total at any time. After
one (or multiple) weighing operations, you can print sub-total using menu item
'33:Print3'. Print pattern is the same as with totals printout, however, the totals
memory is not cleared.
BV-H2322 AA
0630
- 46 -
Display (e.g.)
Key(s); Comments
W4004:Filling
Stopped
(flashes for 20 sec.)
Continue filling with
Net T
55.5 kg
weight already filled
W4104:Filling
Aborted
Net T
59.0 kg Filled weight and filling operation
are balanced and printed. Weighing
is complete.
Filled weight is displayed for a set
timeout; then, GROSS is displayed.
Next filling operation can start after
timeout.
If filled weight exceeds MAX value -
-> weigh hopper is automatically
discharged.
DISOMAT
© Schenck Process GmbH, Darmstadt
Scale Specific Control
'Stop' key
'Start' key
+