English
This items reflects a typical operating sequence of a Discharge Scale.
Action
1. DISOMAT must be in
home position!
2. Select material type and
enter setpoint.
3. Start discharging.
4. If required, stop
discharging.
5. If required, abort
discharging.
6. Terminate discharging.
7. Discharge hopper.
BV-H2322 AA
0630
- 48 -
Display (e.g.)
Key(s); Comments
G
3.5 kg
G
3.5 kg
apr. 1sec.
Scale waits for no-motion and tares
automatically.
Net T
0.0 kg
Scale is tared.
Discharging continues automatically
until setpoint is reached.
W4004:Filling
Stopped
(flashes for 20 sec.)
Continue discharging with
Net T
55.5 kg
weight already
discharged
W4104:Filling
Aborted
Net T
59.0 kg Filled weight and discharging
operation are balanced and printed.
Weighing is complete.
Filled weight is displayed for a set
timeout; then, GROSS is displayed.
Next discharging operation can start
after timeout.
Upon discharge weighing, hopper is
refilled as soon as fill level in
storage hopper falls below the Refill
value.
DISOMAT
© Schenck Process GmbH, Darmstadt
Scale Specific Control
'MatSet' key
'Start' key
'Stop' key
'Start' key
+
'Abort' key
®
Opus – Operating Instructions