English
1. Weight Display including status information
The measured weight is displayed complete with unit, e.g. 357.4 kg. For details,
additional symbols or texts can be output:
Display Meaning
357.4
Weight Value
The weight display shows the weight acquired by the scale.
- 5.4
Negative sign, e.g. with scale relieved if tare has been acquired.
Unit Sign
kg
Unit of weight value, e.g.
ton(t), kilogram(kg), gram(g), pound lbs.(lb), newton (N), kilonewton (kN)
'Scale in Zero Setting Range'
Displayed weight value is in the space of the configured range; see
.
parameter 'Zero Setting Range'. Function Zero Scale is possible; no event
message is displayed.
Stored Tare Value
T
A tare value > 0 has been stored.
Preset Tare Value
PT
Weight value stored in tare memory has not been acquired by scale but in
manual or via EDP.
NET Display
Net
Weight display shows weight of load on scale minus the value stored in tare
memory.
GROSS Display
G
Weight display shows weight of load on scale.
No-Motion
> <
Load on scale is stable within certain limits (scale in no-motion).
Zero Set
Scale is totally relieved.
(Exact zero; GROSS value accurate to ±¼ d)
'Invalid'
xxxxxx
Weight currently invalid
'Overrange' (if 'Legal-for-Trade' parameter = Yes).
Internal weight acquisition continues, all switching functions, e.g. overload
checks, are active now as before.
oooooo
When the 'legal-for-trade' parameter is set = No, the scale also shows
weights even above the maximum readings until it exceeds the rated range.
Afterwards, it shows 'invalid'.
With multi-range/multi-divisional scales, information on active field is
highlighted (range code).
1
to EN 45501
BV-H2322 AA
0630
- 38 -
1
DISOMAT
© Schenck Process GmbH, Darmstadt
General Control
®
Opus – Operating Instructions