General Data - Burkert 8025 Manuel D'utilisation

Masquer les pouces Voir aussi pour 8025:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

180
Fig. 4:
Dimensions in mm of the SE35 electronic module
Table 2: Height H in mm of SE35 electronic module associated to
an S030 fitting-sensor
DN (mm)
06
08
15
H (mm)
134 134 139 137 137 140 144 151 151
10
88
95
20
25
32
40
50
The height H does not
1)
depend on the type of con-
nection or on the material.
English
6.3.2.

General data

Type
Pipe diameter
Type of fitting
Fluid temperature
Fluid pressure
Flow rate measurement
• Measurement range
• Measurement error
with a teach-in
procedure (teach-in
function)
• Measurement error
with K factor of fitting
used
65
• Linearity
• Repeatability
Power supply
Determined in the following reference conditions: fluid = water,
1)
water and ambient temperatures = 20 °C, upstream and down-
stream distances respected, appropriate pipe dimensions.
Type 8025/8035 battery powered
Technicaldata
8025
DN20 (except for DN specified
p.13) to DN400
S020
The fluid temperature may be restricted by the
fluid pressure and by the material of the fitting
used. See Fig. 5 et Fig. 6
The fluid pressure may be restricted by the fluid
temperature and by the material of the fitting
used. See Fig. 5 et Fig. 6
• 0,2 to 10 m/s
• ±0,5 % of the full scale
• ± (0,5% of the full scale + 2,5 % of the
measured value) 1)
• ±0,5 % of the full scale 1)
• ±0,4 % of the measured value
2 batteries of 9 V (6LR61)
Minimum autonomy: 1 year at 20° C
8035
DN6 to
DN65
S030

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

8035

Table des Matières