Type 8025/8035 battery powered
Maintenanceandtroubleshooting
8.6.4.
configuring the filter
This parameter makes it possible to dampen the fluctuations ot the
display.
Ten filters are available.
FiltER
FiltER 0
0......9
FiltER 9
tOtAl
Fig. 20: Diagram of the "FILTER" parameter of the Configuration level
8.6.5.
resetting both totalizers
tOtAl
REs NO
REs YEs
END
Fig. 21: Diagram of the "TOTAL" parameter of the Configuration
level
The daily totalizer can be reset from the Process level (see
chap. 8.5).
→
Choose the filter.
→
Confirm
→
Choose to reset the
two totalizers or not.
→
Confirm
9.
mAinTenAnce AnD
TroubleshooTinG
9.1.
safety instructions
danger
risk of injury due to high pressure in the installation.
• Stop the circulation of fluid, cut off the pressure and drain the
pipe before loosening the process connections.
risk of injury due to electrical voltage.
• Shut down and isolate the electrical power source before car-
rying out work on the system.
• Put the power switch to OFF before carrying out work on the
device.
• Observe all applicable accident protection and safety regulati-
ons for electrical equipment.
risk of injury due to high fluid temperatures.
• Use safety gloves to handle the device.
• Stop the circulation of fluid and drain the pipe before loosening
the process connections.
risk of injury due to the nature of the fluid.
• Respect the prevailing regulations on accident prevention and
safety relating to the use of aggressive fluids.
English
23