Type 8025 / SE35, battery powered
Adjustment,Commissioning
→
When you have done all the settings in this menu, go to the
"END" parameter and press
and to go back to the Process level.
8.7.1
choosing the display language
When the device is energized for the first time, the display language
is English.
LANGUAGE
ENGLiSh
DEUtSCh
FRANçAiS
itALiANO
ESPANOL
UNit
Fig. 14 : Diagram of the "LANGUAGE" parameter of the Para-
meters menu
8.7.2
choosing the flow rate units, the
number of decimals and the units of
the totalizers
When the flow rate units have been changed:
• change the value of the K factor, by hand,
• reset both totalizers, by hand.
ENTER
to save the settings or not
→
Confirm the dis-
played language:
The selected lan-
guage is immediately
active.
The maximal flow rate that can be displayed depends on the
number of decimals chosen:
• 9999 if the number of decimals = 0 or AUTO,
• 999,9 if the number of decimals = 1,
• 99,99 if the number of decimals = 2,
• 9,999 if the number of decimals = 3.
The maximal volume that can be displayed by the totalizers
depends on the chosen units of the volume:
• 9 999 999 if the chosen units of the volume is "litre",
• 999 999 if the chosen units of the volume is "m
"gallon".
The "UNIT" parameter makes it possible to choose:
• the flow rate units.
• a fixed number of decimals (choose 0, 1, 2 or 3) to display the
flow rate in the Process level, or a floating decimal point (choose
"AUTO": the device automatically adjusts the position of the
decimal point depending on the chosen units and the measured
flow rate).
• the volume units of the totalizers if the unit previously chosen is in
litres or in m
.
3
The totalizer values are automatically displayed in gallons if the
flow rate units chosen is in gallons.
English
", or
3
21