Electric wire rope winch >BETA II<
English
6.2. Explanation to drive groups FEM 9.511 for rope drives
The electric wire rope winches are classified according to different drive groups, DIN 15020, FEM 9.511,
ISO4301/1 (see tech. data, page 24 )
Those drive groups refer to the rope drive and all mechanical parts of the winch.
It determines the period of time of safe operation depending on load collective.
running
time /
medium running time per day in
category
hour, related to one year
Term
no.
light
1
medium
2
heavy
3
4
very
heavy
6.3. Calculated operating times acc. to FEM 9.755
DIN 15020/1 FEM 9.511
ISO 4308/1; SO 4301/1
Load collective
line
factor of the load spectrum
light 1 - L1
k = 0,5
1
(km 1 = 0,125 = 0,5 3 )
medium 2 - L2
2
0,5 < k < 0,63
(km 1 = 0,25 = 0,63 3 )
heavy 3 - L3
3
0,63 < k < 0,8
(km 1 = 0,5 = 0,8 3 )
very heavy 4- L4
0,8 < k < 1,0
4
(km 1 = 1 = 1,0 3 )
*)
not included in FEM 9.511
Apart from drive groups, the rope has to be checked and serviced regularly according to
DIN15020, if necessary, replace.
By comparing those data with the actual operating conditions and times the consumed part of
the calculated operating time can be determined
The consumed part of the calculated operation has to be recorded by the operator (e.g. writing,
counting, measuring)
After expire of the calculated working life the winch has to be given a thorough examination
1)
only by manufacturer or competent personnel authorised by manufacturer
design changes under reserve
Symbol
Explanation
exceptionally maximum load,
continuously very small loads
k < 0,50
often maximum load, but
continuously small loads
0,50 < k < 0,63
frequent maximum load,
continuously average loads
0,63 < k < 0,80
continuously maximum load and
adjacent loads
0,80 < k < 1,00
1D m
Drive group
1E m *
M 1
(400) *
800
(200) *
400
(100) *
200
(50) *
100
04.01.401
V
V
V
V
006
012
025
05
≤ 0,12 ≤ 0,25 ≤ 0,5
≤ 1
Drive group
acc. to FEM9.511, DIN15020, ISO4301
1
1
1
1
E m*
E m*
D m
C m
1
1 D m
1
1Bm 1Am 2 m
E m*
C m
1 D m 1 C m 1Bm 1Am 2 m
1 C m 1Bm 1Am 2 m
1C m
1B m
1A m
M 2
M 3
M 4
calculated operation time D (h)
1600 3200 6300 12500 25000 50000 100000
800
1600 3200
400
800
1600
200
400
800
V
V
V
V
1
2
3
4
≤ 2
≤ 4
≤ 8
≤ 16
1Bm 1Am 2 m
3 m
3 m
4 m
3 m
4 m
5 m
3 m
4 m
5 m
2 m
3 m
4 m
M 5
M 6
M 7
6300
12500 25000
3200
6300
12500
1600
3200
6300
1)
page 35
V
5
≥ 16
4 m
5 m
5 m
M 8
50000
25000
12500