Example:
A pressure transducer with 0 ... 400 mbar (nominal pressure) is to be programmed.
The liquid's surface (with a density of 1) is 1 m above the diaphragm at the zero point.
The maximum (span end-point) should be 3 m.
I
=
ca lc
This means that the output must be set to 12 mA during programming.
Calculate
Calibration Value
I calc =
Calibration of span, without display, without pressure
Important
Subject to technical changes without notice.
Operation of Devices without Displays
pressure difference (span) (300 mbar -100 mbar)
--------------------------------------------------------------------------------------------------------------------------------- - 16 mA
Sensors nominal pressure 400 mbar
Activate
Function
Keypad
(2 s)
A change in the zero point has no effect on the adjusted span.
However, if the span end-point is higher than the peak value of the
sensor's nominal pressure range, then the span end-point is fixed at
this peak value and the span is reduced accordingly.
A change in the span setting has no effect on the zero point. The zero
point and span end-point must fall within the sensor's nominal pres-
sure range.
A test / correction of the zero point is suggested after adjusting the
span in order to maintain optimum accuracy.
Pressure Transmitter 8326
Access
Set
Value
current value increases
current value decreases
4 mA
12 mA
+
=
Confirm
Calibration Value
... to I meas = I calc
... to I meas = I calc