Construction; Auxilliary Power; Ambient Conditions - Burkert 8326 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3.3

Construction

Process connections
Materials
Housing
wetted parts:– standard
Internal transmission fluid
Electrical connection
per EN 60 529/ IEC529
Electric protection
3.4

Auxilliary Power

Power supply
3.5

Ambient Conditions

Ambient temperature
Storage temperature
Climate class
Ingress protection per EN 60 529
EMC per
Subject to technical changes without notice.
GB-9
– with a flush
diaphragm
– EHEDG
Pressure Transmitter 8326
G 1/2 B
per DIN 16288 (1/2 NPT)
G 1/2 B
flush diaphragm with O-Ring
(Ranges:
0 ... 6 to 0 ... 600 bar)
G 1 B
flush diaphragm with O-Ring
according to EHEDG
highly resistive, fiberglass-enforced plas-
tic (PBT)
CrNi-steel 1.4571 (316 Ti) and 1.4542
(630 17.4 PH)
CrNi-steel 1.4571 (316 Ti) and O-Ring:
FPM
CrNi-steel 1.4435 (316 L) and O-Ring:
EPDM
– Standard
– EHEDG-version is FDA approved
M 20 x 1.5 cable gland with internal ter-
minal block (see 4.4)
Reverse polarity, overload and short cir-
cuit protection
12 ... 36 V DC
– 40 °C ... + 85 °C
(– 20 °C ... 70 °C with display)
– 40 °C ... + 85 °C
(– 35 °C ... 80 °C with display)
D per DIN IEC 654-1
IP 65 (IP 67 upon request)
EN 50 081-2, EN 50 082-2,
NAMUR NE 21
Technical Data