Lightingprocedureforsideburnerinsidetable(optionalequipment)
1. Open the side burner lid before lighting the side burner.
2. Open the gas cylinder valve by turning anticlockwise (at least two full
turns).
3. Check all gas connections for leaks. See section "Leak check"
4. Press the control knob for the side burner inwards and turn it slowly
anticlockwise to the "MAX" position or until you hear the click of the
ignition system.
5. It is possible to visually check the ignition system. Look at the ignition area
of the side burner at the side from a distance. After the ignition spark was
triggered by the control knob, the gas flowing past is ignited and the side burner is lit.
6. If the side burner does not light immediately, turn the control knob back to "•" OFF and wait 2 minutes
to allow the accumulated gas to disperse. Now you can repeat the ignition procedure.
7.
You can now use the control knob to adjust the flame to suit your particular requirements.
For the lowest setting, you turn the control knob anticlockwise to "MIN".
8. If you do not succeed in lighting the side burner, refer to the section "Troubleshooting".
9. After use press in the control knob (gas valve) for the side burner and turn it clockwise to the position
"•" OFF.
Lightingprocedurefor"PrimeZone"infraredburnerinsidetable
(optional equipment)
1. Open the lid of the infrared burner before you light the Prime Zone.
2. Open the gas cylinder valve by turning anticlockwise (at least two full
turns).
3. Check all gas connections for leaks. See section "Leak check"
4. Press the control knob for the infrared burner inwards and slowly turn it
anticlockwise to the position "MAX".
5. Now light the Prime Zone by pressing the electronic igniter. Keep the
igniter button pressed until the infrared burner lights up and burns.
6. It is possible to visually check the ignition system. Look at the ignition area
of the infrared burner at the side from a distance. After the ignition spark was triggered by the igniter
knob, the gas flowing past is ignited and the infrared burner is lit.
7.
If the infrared burner does not light within 10 seconds, turn the
control knob back to "•" OFF and wait 2 minutes to allow the
accumulated gas to disperse. Now you can repeat the ignition
procedure.
8. You can now use the control knob to adjust the flame to suit your
particular requirements.
For the lowest setting, you turn the control knob anticlockwise to
"MIN".
9. If you do not succeed in lighting the infrared burner, check the
battery or refer to the section "Troubleshooting".
10. After use press in the control knob (gas valve) for the infrared burner and turn it clockwise to the
position "•" OFF.