Fig. 15
WARNING: PRIOR TO LIGHTING, CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS.
USE SOAP AND WATER SOLUTION. DO NOT USE AN OPEN FLAME.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
Before operation, verify thermocouple is securely seated in the safety valve. The thermocouple should
be tightened a
1
/
turn past finger tight. DO NOT OVERTIGHTEN. Overtightening may damage the
4
thermocouple or safety magnet.
TESTING THE GAS SUPPLY SYSTEM
1
When gas supply pressure exceeds
/
psig (3.45 kPa), the range and its individual shutoff valve must
2
be disconnected from the gas supply piping system.
1
When gas supply pressure is
/
psig (3.45 kPa) or less, the range should be isolated from the gas supply
2
system by closing its individual manual shutoff valve until the range is ready for start-up.
FLUE CONNECTIONS
DO NOT obstruct the flow of flue gases from the flue located on the rear of the range. It is recommended
that the flue gases be ventilated to the outside of the building through a ventilation system installed by
qualified personnel.
From the termination of the flue to the filters of the hood venting system, a minimum clearance of 18"
(457 mm) must be maintained.
Information on the construction and installation of ventilating hoods may be obtained from the standard
for the "Removal of Vapors from Commercial Cooking Equipment", NFPA No. 96 (latest edition),
available from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.