7.2 Technical Data AKM2G-2x Series
7.2.1 Technical Data AKM2G-21
U
Parameter
N
Max. Rated Equivalent Line
Voltage
Max. Continuous Torque for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Current for ∆ T
winding = 100°C (1)(2)(4)
Max. Continuous Torque for ∆ T
winding = 60°C (2)(4)
Max. mechanical speed (5)
Peak Torque (1)(2)(4)
Peak Current
120
Rated Torque (speed) (1)(2)(4)
V AC
Rated Speed
Rated Power (speed) (1)(2)(4)
240
Rated Torque (speed) (1)(2)(4)
V AC
Rated Speed
Rated Power (speed) (1)(2)(4)
400
Rated Torque (speed) (1)(2)(4)
V AC
Rated Speed
Rated Power (speed) (1)(2)(4)
480
Rated Torque (speed) (1)(2)(4)
V AC
Rated Speed
Rated Power (speed) (1)(2)(4)
AKM2G Instructions | 7 Technical Data
Tolerance Symbol
Electrical data
Max
V bus
Nom
Tmc
Nom
Imc
Nom
Tmc
Nom
Nmax
Nom
Tp
Nom
Ip
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Trtd
Nrtd
Prtd
Kollmorgen | kdn.kollmorgen.com | August 2020
Units
AKM2G
21D
21E
V ac
480
240
Nm
0.636
0.642
ib-in
5.62
5.68
Arms
2.17
2.73
Nm
0.494
0.498
lb-in
4.37
4.41
rpm
8000
8000
Nm
1.78
1.79
lb-in
15.7
15.8
Arms
8.66
10.9
Nm
0.583
0.568
lb-in
5.16
5.02
rpm
4800
6200
kW
0.293
0.369
Hp
0.393
0.494
Nm
0.534
0.534
lb-in
4.73
4.73
rpm
8000
8000
kW
0.448
0.448
Hp
0.600
0.600
Nm
0.525
lb-in
4.64
rpm
8000
kW
0.439
Hp
0.589
Nm
0.520
lb-in
4.60
rpm
8000
kW
0.435
Hp
0.584
21G
120
0.649
5.75
4.18
0.503
4.45
8000
1.79
15.9
16.7
0.545
4.82
8000
0.456
0.612
173