– NO deactivated)
8. OPT warning:
-
to display the alarm indicator light in the main
working screen (YES enabled – NO disabled)
9. Disable laser:
-
to disable the lasers when faulty. If disabled,
the dimensions must be set manually and the
weights applied in the 12 o'clock position
10. Automatic position search (RPA):
-
to enable automatic position search at the end
of the spin (YES enabled – NO disabled)
11. dimension measurement with C unlocking:
-
to set automatic dimension measurement every
time the automatic wheel clamping system is
activated (YES activated – NO deactivated).
12. enables/disables the rim search
-
for activating detection of ONLY the rim mounted
on the machine while measuring the dimensions
(YES activated – NO deactivated)
13. automatic light
-
to activate operation of the LED light as required
(YES activated – NO deactivated)
-
when the programme is active, the light is enabled
in the following cases:
-
during the entire measuring cycle, with the
exception of during dimension acquisition;
-
in CP (centred position) for an additional 30
seconds;
-
during the Hidden Weight programme when
selecting the two planes behind the spokes.
14. Set factory data:
-
to reset the initial machine configuration Machine
calibrations are not modified.
To save the new settings, press the Save
button and press the Exit button
back to the main working screen.
6.3. Unbalance sensitivity calibration
This procedure should be performed whenever calibra-
70
tion appears to be out of the tolerance range or when
the machine requires this procedure to be performed
by displaying the E 1 error message.
Calibrate as follows:
-
select the sensitivity calibration icon in the
configuration programme menu;
-
Fit a wheel of average dimensions (diameter
no less than 14") and preferably with a small
imbalance only on the wheel balancer.
-
perform a spin;
-
At the end of the spin, fix the calibration weight
supplied with the machine on the shaft assembly
bell as indicated in figure 22.
-
perform a second spin;
-
At the end of the spin, change the position of
the calibration weight on the shaft assembly bell
as indicated in figure 23