Parameter
No Format
Dec delta time [s]
30
T current lim + [%]
8
T current lim - [%]
9
Encoder 1 type
415
Sinusoidal
Digital
Encoder 1 pulses
416
Speed base value [FF]
45
Save parameters
256
Enable drive
314
Enabled
Disabled
Start/Stop
315
Start
Stop
Ramp ref (d) [FF]
109
Ramp output (d) [FF]
112
Speed ref (d) [FF]
115
(Speed ref var)
Actual spd (d) [FF]
119
(Act spd value)
F act spd (d) [FF]
925
Act spd filter [s]
923
Ramp ref (rpm)
110
Ramp outp (rpm)
113
Speed ref (rpm)
118
Actual spd (rpm)
122
Enc1 speed [rpm]
427
Enc2 speed [rpm]
420
F act spd (rpm)
924
Act spd filter [rpm]
923
Ramp ref (%)
111
Ramp output (%)
114
Speed ref (%)
117
Actual spd (%)
121
DC link voltage [V]
227
Active power [%]
229
Output voltage [V]
233
Output frequency [Hz]
324
Motor current [A]
231
Torque [%]
230
T current ref [%]
41
T curr (%)
927
F T curr (%)
928
T curr filter [s]
926
Flux [%]
234
Heatsink temp [°C]
881
Regulation temp [°C]
1147
Intake air temp [°C]
914
Digital I/Q
-
Dig input term
564
Dig input term 1
565
Dig input term 2
566
Dig input term 3
567
Dig input term 4
568
Dig input term 5
569
Dig input term 6
570
Dig input term 7
571
Value
min
max
U16
0
65535
U16
0
F
U16
0
F
I16
0
1
Float*
600
9999
U32***
1
16383
U16
0
65535
MONITOR
U16
0
1
U16
0
1
MONITOR \ Measurements \ Speed \ Speed in DRC []
I16
-32768
32767
I16
-32768
32767
I16
-32768
32767
I16
-32768
32767
I16
-32768
32767
Float
0.001
0.100
MONITOR \ Measurements \ Speed \ Speed in rpm
I16
-32768
32767
I16
-32768
32767
I16
-32768
32767
I16
-8192
8192
I16
-8192
8192
I16
-8192
8192
I16
-32768
32767
Float
0.001
0.100
MONITOR \ Measurements \ Speed \ Speed in %
Float
-200.0
+ 200.0
Float
-200.0
+ 200.0
Float
-200.0
+ 200.0
Float
-200.0
+ 200.0
MONITOR \ Measurements
U16
0
999
Float**
-500
500
Float**
0
500
Float
0.0
500.0
Float
0.00
S
Float
-500
500
I16
-500
500
I16
-500
500
I16
-500
500
Float
0.001
0.250
Float*
0.00
100.00
I16
-
-
I16
-
-
U16
-
-
MONITOR \ I/O
U16
0
65535
U16
0
1
U16
0
1
U16
0
1
U16
0
1
U16
0
1
U16
0
1
U16
0
1
——— Liste des paramètres ———
Access via
Keyp.
RS485/
Factory
BUS/
Opt2-M
1
R/W
S
R/W
S
R/W
Digital (1)
R/Z
0
1
1024
R/Z
1500
R/Z
-
C
Disabled (0)
R/W
1
0
Stop (0)
R/W
1
0
-
R
-
R
-
R
-
R
-
R
0.001
R/W
-
R
-
R
-
R
-
R
-
R
-
R
-
R
0.001
R/W
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
0.100
R/W
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
Terminal
Opt2-A
/PDC
-
-
IA
R/W
IA
R/W
-
-
-
R
-
R
-
-
12
R/W
H
L
13
R/W
H
L
-
R
-
R
-
R
-
R
-
R
-
-
QA
R
QA
R
QA
R
QA
R
-
R
-
R
QA
R
-
-
-
-
-
-
-
-
-
-
QA
-
QA
R
QA
R
-
-
QA
-
QA
-
QA
R
QA
R
QA
R
-
-
QA
R
-
-
-
-
QA
-
-
-
-
R
-
R
-
R
-
R
-
R
-
R
-
R
-
R
127
Ch.8