WASHING SUPPLY CONNECTION
To carry out this operation, proceed as follows:
1. Connect red pipe (A) to pipe (B) and fi t cone (C)
into the cleaner tank (D).
2. Connect blue pipe (E) to pipe (B) and fi t cone
(C) into the sanitizing cleaner tank (F).
Use the cleaner and sanitizer supplied by the
appliance manufacturer for the best results.
The chemical composition of the products referred
to above is as follows:
Cleaner: caustic soda, concentration less than 20%.
Sanitizing cleaner: containing citrates and organic
sequestering agents, less than 15%.
IMPORTANT ________________________
The
use
of
products
compositions may damage the system and
the oven walls, and any residues deposited
may contaminate foods.
B
C
D
with
different
A
E
F
CONNECTING THE GAS EXHAUST VENT
IMPORTANT _________________________
Make the connection in compliance with
all relevant local and legal requirements,
using
appropriate
materials.
IMPORTANT _________________________
Maximum exhaust gas temperature at the
outlet is approximately 750°F.
C
Minimum
12"
CONNECTING TO A
FAN EXTRACTOR HOOD
Position the appliance underneath hood (C) as
shown in the diagram.
IMPORTANT _________________________
The
gas
supply
automatically
when
extraction system is switched on.
Combination Oven Installation and Operation Manual
Section 4
Handling and Installation
and
recommended
valve
must
open
the
fan
of
the
23