Section 4
Handling and Installation

APPLIANCE INSTALLATION

All installation stages must be considered based on
the site survey and specifi c installation location of the
unit. Before starting these stages, as well as deciding
the place of installation, the person authorized to
perform these operations must organize a "safety
plan" to protect people directly involved, and must also
ensure strict compliance with all legal requirements,
especially those relating to mobile work-sites.
The location of the installation must have all the
utility supply, ventilation, extraction and production
residue venting connections required. In addition,
the location must be suitably lit and meet all local
health department and hygiene requirements to
prevent the contamination of foods.
It is suggested to mark the location of each individual
appliance or subassembly prior to installation.
Install in accordance with the relevant local codes,
regulations and specifi cations in the country of use.
WARNING Fire risk! If the appliance is
positioned near walls, partitions, kitchen cabinets,
decorative trim, etc. these items must be made
from a nonfl ammable material. All fi re prevention
regulations must be strictly observed.
IMPORTANT _________________________
Install the appliance on a stand (available
as an option) and position it as shown in the
diagram (For version FX61-101-82-122 only).
If the oven is installed in the middle of a room, please
leave at least a distance of 20 inches between its
back and other appliances.
IMPORTANT _________________________
All clearance requirements are the same for
combustible or non-combustible constructions.
Suitable for installation on combustible fl oors.
3.94 in
20
in
18 Combination Oven Installation and Operation Manual
IMPORTANT _________________________
During installation of the appliance, take
care to prevent all possible obstruction of
the combustion air intake A.
A
CASTER - MOUNTED OVENS
For an appliance equipped with casters, the
installation must be made with a connector that
complies with the Standard for Connectors for
Movable Gas Appliances, ANSI Z21.69 CSA 6.16,
and a quick-disconnect device that complies with
the Standard for Quick-Disconnect Devices for Use
With Gas Fuel, ANSI Z21.41 CSA 6.9. Adequate
means must be provided to limit the movement of
the appliance without depending on the connector
and the quick-disconnect device or its associated
piping to limit appliance movement.

ROOM VENTILATION

The room where the appliance is installed must have air
inlets to ensure that the appliance can operate correctly
and provide the necessary air exchange in the room.
Air inlets must be of appropriate size, protected by
gratings and placed so that they cannot be obstructed.
3.94 in