7.4 - Level one programming (ON-OFF functions)
Level 1 functions are all factory set to "OFF". However, they can be changed at
any time as shown in Table 6. Follow the procedure carefully, as there is a maxi-
01. Press the key "Set" and hold it down (approx. 3 s);
02. Release the "Set" key when "L1" LED starts flashing;
03. Press keys "▲" or "▼" to move the flashing LED onto the LED representing the function which is to be changed;
04. Press the "Set" key to change the state of the function:
(short flashing = OFF; long flashing = ON);
05. Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
Note – Points 3 and 4 can be repeated during the same programming phases in order to set other functions to ON or OFF.
7.5 - Level two programming (adjustable parameters)
The adjustable parameters are factory set as shown in the table 7 with: "
However, they can be changed at any time as shown in Table 8. Follow the pro-
Imput
Parameter LED
LED
L1
Pause
Time
L2
Step-by-
step
L3
Motor
speed
L4
Open Gate
Indicator
Output
L5
Motor
force
8 – English
TABLE 6 - Changing ON-OFF functions
TABLE 7 - Level two functions (adjustable parameters)
Value
(level)
L1
5 seconds
L2
15 seconds
L3
30 seconds
L4
45 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
180 seconds
L1
Open – stop – close – stop
L2
Open – stop – close – open
L3
Open – close – open – close
L4
Condominium operation
L5
Condominium operation 2 (more than 2" causes stop)
L6
Step-by-Step 2 (less than 2" causes partial opening)
L7
Man present
L8
"Semiautomatic" opening, "Man present " closing
L1
Very slow
L2
Slow
L3
Medium
L4
Fast
L5
Very fast
L6
Extremely Fast
L7
Opens "Fast"; closes "slow"
L8
Opens "Extremely Fast" Closes "Fast"
L1
Open Gate Indicator Function
L2
On if leaf closed
L3
On if leaf open
L4
Active with 2
nd
radio output
L5
Active with 3
rd
radio output
L6
Active with 4
th
radio output
L7
Maintenance indicator
L8
Electric lock
L1
Super light gate
L2
"Very light" gate
L3
"Light" gate
L4
"Average" gate
L5
"Average-heavy" gate
L6
"Heavy" gate
L7
"Very heavy" gate
L8
"Super heavy" gate
mum time of 10 seconds between pressing one key and another. If a longer
period of time lapses, the procedure will finish automatically and memorize the
modifications made up to that stage.
cedure carefully, as there is a maximum time of 10 seconds between pressing
one key and another. If a longer period of time lapses, the procedure will finish
"
automatically and memorize the modifications made up to that stage.
SET
3 s
SET
L1
or
SET
10 s
Description
Adjusts the pause time, namely the
time which lapses before automatic
closure. This will only have an effect
if automatic closing is active.
Manages the sequence of controls
associated to the Step-by-Step input
or to the 1st radio command.
Adjusts the speed of the motor during
normal travel.
Adjusts the function associated with
the S.C.A. output (whatever the
associated function may be, the out-
put supplies a voltage of 24V –30
+50% with a maximum power of 4W
when active).
Adjusts the system which controls
the motor force in order to adapt it to
the weight of the gate. The force
control system also measures the
ambient temperature, automatically
increasing the force in the event of
particularly low temperatures.