Additional Information; Programming Keys; Programming; 7.2.1 Level One Functions (On-Off Functions) - Nice Robus 600 Instructions Et Avertissements Pour L'installateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7) Additional information

Programming, personalisation and how to look for and deal with faults on the ROBUS will be dealt with in this chapter.

7.1) Programming keys

The ROBUS control unit feature three keys that can be used to com-
mand the control unit both during tests and programming.
The "OPEN" key enables the user to control the opening
Open
of the gate or move the programming point upwards.
The "STOP" key enables the user to stop the manoeuvre. If pressed down
Stop
for more than 5 seconds it enables the user to enter programming.
Set
The "CLOSE" key enables the user to control the closing of the gate or
Close
move the programming point downwards.

7.2) Programming

A number of programmable functions are available on the ROBUS
control unit. The functions are adjusted using 3 keys set on the con-
trol unit: [▲] [Set] [▼] and are used by means of 8 LEDs: L1....L8.
The programmable functions available on ROBUS are set out on 2
levels:
7.2.1) Level one functions (ON-OFF functions).
Table 7: programmable function list: level one
Led
Function
Automatic Closing
L1
Close After Photo
L2
Always Close
L3
Stand-By
L4
Peak
L5
Pre-flashing
L6
"Close" becomes
L7
"Open partially"
"Slave" mode
L8
During the normal functioning of the ROBUS, LEDs L1....L8 will either be on or off depending on the state of the function they represent.
For example, L1will be on if the "Automatic Closing" function is active.
Description
This function causes the door to close automatically after the programmed time has lapsed. The factory
set Pause Time is 30 seconds, but can be changed to 5, 15, 30, 45, 60, 80, 120 or 180 seconds. If the
function is inactive, functioning will be "semi-automatic".
This function enables the gate to be kept open for the necessary transit time only. In fact the "Photo"
always causes an automatic closure with a pause time of 5s (regardless of the programmed value).
The action changes depending on whether the "Automatic closing" function is active or not.
When "Automatic Closing" is inactive: The gate always arrives to the totally open position (even if
the Photo disengages first). Automatic closing with a pause of 5s occurs when the Photo is disengaged.
When "Automatic Closing" is active: The opening manoeuvre stops immediately after the
photocells have disengaged. After 5 seconds, the gate will begin to close automatically.
The "Close after photo" function is always disabled in manoeuvres interrupted by a Stop command.
If the "Close after photo" function is inactive the pause time is that which has been programmed or there
is no automatic closing if the function is inactive.
The "Always Close" function will trigger, and the gate will close if an open gate is detected when the
power supply returns. If the function is inactive when the power supply returns, the gate will remain still.
Stand-By
This function enables the user to lower consumption to a very minimum. It is particularly
useful in cases when the buffer battery is being used. If this function is active, the control unit will switch
the BLUEBUS output (and consequently the devices) and all the LEDs off one minute after the end of the
manoeuvre. The only LED which will remain on is the BLUEBUS LED which will simply flash more slowly.
When a command arrives, the control unit will reset to complete functioning. If this function is inactive,
there will be no reduction in the consumption.
If this function is activated, the gradual acceleration at the beginning of each manoeuvre will be disconnected.
It enables the peak thrust and is useful whenever static friction is high, e.g. if snow or ice are blocking the
leaf.If the thrust is inactive, the manoeuvre will start with a gradual acceleration.
With the pre-flashing function, a 3 second pause is added between the flashing light switching on and
the beginning of the manoeuvre in order to warn the user, in advance, of a potentially dangerous
situation. If pre-flashing is inactive, the flashing light will switch on when the manoeuvre starts.
By activating this function all "close" commands ("CLOSE" input or radio command "close")
activate a partial opening manoeuvre (see LED L6 on table 9).
By activating this function ROBUS becomes "Slave": in this way it is possible to synchronise the
functioning of two motors on opposite leaves where one motor functions as Master and the other as
Slave; for further information see paragraph "7.3.5 ROBUS in "Slave" mode".
23
Level one: the functions can be adjusted in modes ON-OFF (active
or inactive). In this case, each of the LEDs L1....L8 indicates a func-
tion. If the LED is on, the function is active, if off the function is inac-
tive. See Table 7.
Level two: the parameters can be adjusted on a scale of values
(from 1 to 8). In this case, each of the LEDs L1...L8 indicates the
value set (there are 8 possible settings). Please refer to Table 9.