7 Additional Information; 7.1 Programming Keys; Programming; 7.2.1 Level One Functions (On-Off Functions) - Nice Spin10KCE Instructions Et Recommandations Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 54
7) Additional information
Programming, personalisation and how to look for and deal with faults on the SPIN will be dealt with in this chapter.
7.1) Programming keys
The SPIN control unit feature three keys that can be used to com-
mand the control unit both during tests and programming.
RADIO
the transmitters used with SPIN can be memorised and cancelled by means
of the "RADIO " key.
Stop
The "STOP" key enables the user to stop the manoeuvre; if pressed down for
SET
more than 5 seconds it enables the user to enter programming.
PP
The "Step-by-Step" key enables the user to control the opening and closing
of the door or move the programming point upwards and downwards.

7.2) Programming

A number of programmable functions are available on the SPIN con-
trol unit. The functions are adjusted using 2 keys set on the control
unit: [
] and [Set] are displayed by means of 3 LEDs: L1, L2,
L3.
The programmable functions available on SPIN are set out on 2 levels:
Level one: the functions can be adjusted in modes ON-OFF (active
or inactive). In this case L2 and L3 LED's indicate a function. If the
LED is on, the function is active, if off the function is inactive. See
Table 15. The L1 LED indicates the radio status and is only used for
the second level functions.
7.2.1) Level one functions (ON-OFF functions).
Table 15: list of programmable functions: Level one
LED Function
L1
---
L2
Motor speed
L3
Automatic Closing
During the normal functioning of the SPIN, LEDs L2 and L3 will either be on or off depending on the state of the function they represent.
For example, L3 will be on if the "Automatic Closing" function is active.
7.2.2) Level one programming (ON-OFF functions).
Level 1 functions are all factory set to "OFF". However, they can be changed at any time as shown in Table 16. Follow the procedure care-
fully, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of time lapses, the procedure will
finish automatically and memorize the modifications made up to that stage.
Table 16: changing ON-OFF functions
1.
Press the key [Set] and hold it down (approx. 3 s)
2.
Release the [Set] key when L1 LED starts flashing
3.
Press the [
] key to move the flashing LED onto the LED representing the function which
is to be changed
4.
Press the [Set] key to change function status (short flash = OFF; long flash = ON)
5.
Wait 10 seconds before leaving the program to allow the maximum time to lapse.
Note: Points 3 and 4 can be repeated during the same programming phases in order to set other functions to ON or OFF.
16
Description
---
The speed of the motor can be chosen by means of this function: "fast", "slow".
The set speed is "slow" until the function is activated.
This function causes the door to close automatically after the programmed time has lapsed. The factory set
Pause Time is 30 seconds, but can be changed to 15 or 60 seconds (as shown in Table 17).
If the function is inactive, functioning will be "semi-automatic".
37
Level two: the parameters can be adjusted on a scale of values
(from 1 to 3). In this case, each of the L1, L2 and L3 indicates the
value set (there are 3 possible settings). Please refer to Table 17.
Example
SET
3s
L1
SET
SET
10s