8.4 - Level 1 programming (ON-OFF functions)
By default, level 1 functions are all set to OFF, but can be modified at any time
as described in Table 6. Take care during modification procedures, as there is a
01. Press and hold the "Set" key for about 3 seconds;
02. Release the "Set" key when the "L1" LED start to flash;
03. Press keys "s" or "t" to move the flashing LED onto the LED representing the function which is to be changed;
04. Press the "Set" key to change the status of the function: (short flashing = OFF; long flashing = ON);
05. Wait 10s to exit the programming mode automatically after the maximum time interval.
Note – Points 3 and 4 can be repeated during the same programming phases in order to set other functions to ON or OFF.
8.5 - Level 2 programming (adjustable parameters)
The adjustable parameters are factory set as shown in the Table 7 with: "
but can be modified at any time as shown in Table 8. Take care during modifi-
Input LED Parameter LED
L1
Pause
Time
L2
Function
STEP BY
STEP
L3
Speed
of motor
L4
Output
S.C.A.
L5
Force
of motor
8 – English
TABLE 6 - Changing ON-OFF Functions
TABLE 7 - Level 2 functions (adjustable parameters)
Value
(level)
L1
5 seconds
L2
15 seconds
L3
30 seconds
L4
45 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
180 seconds
L1
Open – stop – close – stop
L2
Open – stop – close – open
L3
Open – close – open – close
L4
Apartment block
L5
Apartment block 2 (more than 2" generates stop)
L6
Step-by-Step 2 (less than 2" causes partial opening)
L7
Hold-to-run
L8
"Semi-automatic" opening, "Man present " closing
L1
Very slow
L2
Slow
L3
Medium
L4
Fast
L5
Very fast
L6
Extremely Fast
L7
Opens "Fast"; closes "slow"
L8
Opens "Extremely Fast" Closes "Fast"
L1
Open Gate Indicator Function
L2
On if leaf closed
L3
On if leaf open
L4
Active with 2nd radio output
L5
Active with 3rd radio output
L6
Active with 4th radio output
L7
Maintenance indicator
L8
Electric lock
L1
Super light gate
L2
"Very light" gate
L3
"Light" gate
L4
"Average" gate
L5
"Averageheavy" gate
L6
"Heavy" gate
L7
"Very heavy" gate
L8
"Super heavy" gate
maximum time interval of 10 seconds between pressing one key and another;
otherwise the system exits the procedure automatically memorising the chang-
es made up to that time.
cation procedures, as there is a maximum time interval of 10 seconds between
pressing one key and another; otherwise the system exits the procedure auto-
"
matically memorising the changes made up to that time.
SET
3 s
SET
L1
or
SET
10 s
Description
Adjusts the pause time, namely the
time which lapses before automatic
closure. Is effective only if automatic
closure is enabled.
Manages the sequence of controls
associated to the Step-by-Step input
or to the 1st radio command.
Adjusts the speed of the motor during
normal travel.
Adjusts the function associated with
S.C.A. output. (whatever the associ-
ated function may be, the output
supplies a voltage of 24V –30 +50%
with a maximum power of 4W when
active).
Adjusts the system which controls
the motor force in order to adapt it
to the weight of the gate. The force
control system also measures the
ambient temperature, automatically
increasing the force in the event of
particularly low temperatures.