Models HSCU2GC - HSCU2C: TECHNICAL CHARACTERISTICS
– CLASS II DEVICES
9.1 - POWER SUPPLY, BATTERIES AND SYSTEM AUTONOMY
Primary power: the control panels have type A power supplies with the fol-
lowing specifications:
• Input voltage: 230V AC -15%+10% - 50/60 Hz – draw 0 .15 A
• Output voltage: 14 .4 V DC – ripple max 27 mVpp
• Max . current delivery: 0 .75A
Electronic card draw: 0 .06A
• Max . current available for wired peripherals (do not exceed!): 0 .12A
• Max . current available for backup battery charging: 0 .57A
Secondary power: standard sealed/rechargeable lead acid battery, 12V
2 .2Ah - flammability class UL94-HB
• Max . autonomy during power failure (compliant with EN 50131-3:2009): 12 h
• Max . recharge time (compliant with EN 50131-3:2009): 3 h
• Battery low charge warning at 10 .9V and charged indication at 11 .4V
9.2 - ELECTRONICS COMMON TO BOTH CONTROL UITS
The 34154 (HSCU2GC) - 34156 (HSCU2C) electronics cards are connected to:
• power cable connector 14 .4V and 12V
• internal siren connector
The following may be connected to the cards:
• a PC for programming, using cable code HSA1 (temporary connection)
• pre-amplified microphone for remote listening in another room
• PSTN incoming phone connector, directly from the outside line . Alternatively,
a HSA2 card for extending the phone line inwards
• all cables required to install wired peripherals, connected to the main terminal
block .
The unit has a slot for a removable non-volatile EEprom, can be used to avoid
losing data when the control panel is replaced . Insert the SIM into its slot (mod-
el HSCU2GC) .
9.3 - OTHER TECHNICAL SPECIFICATIONS
Current draw: 55mA in stand-by and without wired connections - 125mA with
display backlighting - 500mA in alarm
Alarm inputs
• wireless: up to 99 programmable detectors, immediate, delayed or AND,
with 6 alarm zones A-B-C-D-E-F or the 24H Panic, 24H Robbery and Technical
Alarm zones .
• wired: 6 double balanced lines (1-6), freely programmable over the 6 zones
A-B-C-D-E-F .
1 balanced input for FAULT warnings (24H)
Wireless tampering: receives the tampering signal from each detector
- receives the "present" signal every 28 minutes and the battery low signal
(SUPERVISION) when appropriate .
Alarm outputs:
• wireless: 72 bit coded digital signals for "alarm" - "full arming" - "partial arm-
ing" - "disarming" + 16 custom coded commands
• wired: 1 for siren command 12V 0 .5A - 1 fro self-powered siren 14V – 1 for
on-board siren
Supplementary outputs: two programmable relays for accessory free
exchange functions max . 500mA 12V .
Control inputs: 1 for connection of supplementary electronic/electromechani-
cal activation controller with at least 300 combinations
RF anomalies: continuous, simultaneous and programmable monitoring of
the two working frequencies
Event log: last 200 events, FIFO – non volatile memory .
Timers: programmable delays from 1 to 99 seconds - programmable input
delay on each detector, 1 to 45 seconds - general alarm time 3 minutes fixed -
programmable 24 h clock
Displays: available via touch screen HSTS2, functions to identify each indi-
vidual peripheral device
Commands: on the HSTS2 wireless touch screen
Internal siren: 106 dB alarms siren
Acoustic signals: voice messages for communicating with the user + low
power buzzer
RF reception/transmission: quartz controlled DualBand – 72 bit factory
coded digital codes self-learnt by microprocessor - legally compliant frequency
and power

TECHNICAL SPECIFICATIONS

Wireless range:100m free range without background disturbance on band -
wireless range may be considerably reduced in interiors, partly due to the loca-
tion of the devices relative to the building structures .
Telephone section: see chapter 4 - 6 .5 - 6 .6
Dimensions: 307 x 200 x 53 mm
Weight: 2 .1 kg
Enclosure: ByBlend
Temperature: operating/storage -10° to +40°C - Humidity 95%
Models HSCU2GW and HSCU2W: TECHNICAL SPECIFICA-
TIONS
9.4 - Models HSCU2GW - HSCU2W: ALKALI BATTERY POW-
ERED (code HSPS1)
• Output voltage: 9V
• Output voltage: > 12Ah
Battery life: the battery life is inversely proportional to the number of peripher-
als, that of peripherals of other contiguous systems (in radio range) and the
number of operations effected on a regular basis .
We give below the mean battery life in months, considering 2 activations and 2
deactivations a day and 12 alarms a year:
Number of peripherals
9.5 - ELECTRONICS COMMON TO BOTH CONTROL UITS
The 34155 (HSCU2GW) - 34157 (HSCU2W) electronics cards are connected
to:
• irreversible 9V power cable connector to battery pack
• internal siren connector
The following may be connected to the cards:
• a PC for programming, using cable code HSA1 (temporary connection)
• PSTN incoming phone connector, directly from the outside line . Alternatively,
a HSA2 card for extending the phone line inwards
The unit has a slot for a removable non-volatile EEprom, can be used to avoid
losing data when the control panel is replaced . Insert the SIM into its slot (mod-
el HSCU2GW) .
9.6 - OTHER TECHNICAL SPECIFICATIONS
Current draw: 180 - 220uA in stand-by - max 400mA in alarm with GSM
operating - max 200mA with PSTN operating
Wireless alarm inputs: up to 99 programmable detectors, immediate,
delayed or AND, over 6 alarm zones A-B-C-D-E-F (wireless only) or the 24H
Panic, 24H Robbery and Technical Alarm zones .
Tampering: receives the tampering signal from each detector - receives the
"present" signal every 28 minutes and the battery low signal (SUPERVISION)
when appropriate .
Alarm outputs: 72 bit coded digital signals for "alarm" - "full arming" - "partial
arming" - "disarming" + 16 custom coded commands
RF anomalies: continuous, simultaneous and programmable monitoring of
the two working frequencies
Event log: last 200 events, FIFO – non volatile memory
Timers: programmable delays from 1 to 99 seconds - programmable input
delay on each detector, 1 to 45 seconds - general alarm time 3 minutes fixed -
programmable 24 h clock
Displays: available via touch screen HSTS2, functions to identify each indi-
vidual peripheral device
Commands: on the HSTS2 wireless touch screen
Internal siren: 106 dB alarm siren + low volume warning buzzer
Acoustic signals: voice information for user and installation guide
RF reception/transmission: quartz controlled DualBand – 72 bit factory
coded digital codes self-learnt by microprocessor - legally compliant frequency
and power
Wireless range: 100m free range without background disturbance on band
- wireless range may be considerably reduced in interiors, partly due to the
location of the devices relative to the building structures .
Wired connection: PSTN phone line (ADSL as well with suitable filters)
Telephone section: see chapter 4 - 6 .5 - 6 .6
HSCU2GW
10
39
20
31
30
25
40
21
HSCU2W
41
32
26
22
English – 33