Technical Specifications - Nice mindy TT0 Instructions Et Recommandations Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
If you need to delete all the data contained in the memory of the control unit, carry out the following procedure.
The memory can be deleted:
• with a non-memorised transmitter starting from point A.
• with a previously memorised transmitter starting the procedure from point N° 1
The following can be deleted:
• only the transmitter codes, finishing at point N° 4
• all data (transmitter codes, directions, wind levels, TTBUS addresses, etc.), completing the procedure.
Table "A5"
Memory deletion (fig. 8)
A
Switch the motor off, activate the Step-by-Step input and keep it active until the end of
the procedure
B
Power the motor and wait for the 2 initial beeps
Press and hold down button ■ of a transmitter until you hear a beep
1
(after about 5 seconds)
Hold down the ▲ button of the transmitter until you hear 3 beeps; release the ▲ button
2
exactly during the third beep
Hold down the ■ button of the transmitter until you hear 3 beeps; release the ■ button
3
exactly during the third beep
Hold down the ▼ button of the transmitter until you hear 3 beeps; release the ▼ button
4
exactly during the third beep
If you wish to delete all the data, press the ▲ and ▼ buttons together within 2 seconds and
5
then release them.
After a few seconds 5 beeps signal that all the memorised codes have been deleted.
4) What to do if...
a small troubleshooting guide!
When the board powered, the 2 beeps will not be heard
and the Step-by-Step input does not control any move-
ment.
Check the control unit is correctly powered: mains voltage must be
present between terminals 6-7, a voltage of about 24Vdc must be
present between terminals 8-10 with the Step-by-Step button dis-
connected. Check the 5A fuse F1 if necessary.

5) Technical specifications

Electronic control unit
Power input
Maximum power of motors
Signal voltage (step-by-step, sensors)
Working temperature
Dimensions / weight
Protected to "IP"
Wind sensor (anemometer) levels
Length of signal cables (step-by-step, sensors)
Radio receiver
Frequency
Coding
Range of ERGO and PLANO transmitters
Nice S.p.a. reserves the right to modify its products without any notice
After a radio command, 6 beeps are heard and the
manoeuvre does not start
The radio control unit is out of sync, repeat the transmitter code
storing procedure.
After a command, 10 Beeps sound and then the manoeu-
vre begins
The self-diagnosis of the stored parameters has revealed a fault
(TTBUS addresses, wind speed and sun power, directions are incor-
rect). Check and repeat programming if necessary
: 230Vac 50/60Hz or 120Vac 50/60 Hz depending on the versions
(see value on label)
: 600W for 230Vac version; 400W for 120Vac version
: Approx. 24Vdc
: -10 ÷ 70 °C
: 120 x 80 x 50
300 g
: 55 (casing undamaged)
: Approx. 30 or 15 or 45 km/h (with anemometer at 0.4 Hz per km/h)
: max. 30m if near other cables, otherwise 100m
: 433.92 MHz
: 52 Bit rolling code FLOR
: Estimated 200 m in the open air without obstacles and 35 m inside buildings.
GB
Example
PP
5s
within 2 s
5

Publicité

Table des Matières
loading

Table des Matières