6.7 - Settings
This menu (fig. 43) is used to make operational and other settings, some of
which are accessible to the user . Caution! - For reasons of compliance with
EN50131, certain functions are mandatory and limited as indicated, and non-
compliant settings are not accepted .
15
43
Devices
Messages
Phone book
Settings
Digital Prot.
Event List
Test
6.7.1 - Automatic arming
Enables timed (user settable) arming of the control panel (total or partial) . Dis-
arming is always manual .
Caution! – Make sure the control panel's date and time are correct .
01. Select "Automatic arming" .
02. In the next page, touch "Arm" and select "YES"; then confirm with "OK" .
03. Touch "Zones" and specify the zones to be armed; confirm again with
"OK" .
04. Touch "Hour" and specify the hour at which the alarm system is to be
armed; confirm with "OK" .
05. Specify the minutes, and confirm once more with "OK" .
06. Confirm the entire procedure one last time with "OK" .
6.7.2 - Exit delay
Defines the delay between the arming and actual operativity of the alarm sys-
tem, so as to allow persons to exit the building without tripping the alarm sys-
tem . The factory setting is a 60 second delay .
01. Select "Exit delay" .
02. In the next page, enter the time in seconds (0 to 99) and confirm with "OK" .
6.7.3 - Exclusion
6.7.3.1 - Excluding wireless detectors
In case of need, you can disable a detector and re-enable it at a later time . This
does not delete it, but prevents it from being used (alarms sent by these sen-
sors are not tracked even in the Events List) .
24 – English
EVENT
Control panel battery low
Detector battery low
No supervision
Radio disturbance
System armed (message sent only when
system is armed by phone)
System disarmed (message sent only when
system is disarmed by phone)
Power failure
Power restored
No GSM network
No successful call on PSTN line
Periodic message (control panel OK)
SIM validity warning
Automatic arming
Exit delay
Exclusion
Exclude sensors
Periodic mess.
Exclude wired inputs
Alarm type
Outputs
Relay
Radio interference
Timer
Supervision
Radio outputs
Power failure
Installer code
Volume
Date and time
Telephone line
Arming block
Wired inputs
SET EN50131
Firmware version
System reset
TABLE 7
DESCRIPTION
CONTROL PANEL BATTERY LOW
PERIPHERAL UNIT BATTERY LOW
NO SUPERVISION
RADIO DISTURBANCE DETECTED
CONTROL PANEL ARMED
CONTROL PANEL DISARMED
POWER FAILURE
RESTORE MAINS
NO GSM NETWORK
NO SUCCESSFUL CALL ON PHONE LINE
PERIODIC CALL OK
SIM EXPIRY
01. Select "Exclude" .
02. Select "Exclude detectors"
03. From the list, select the detector and set it to "Enabled" or "Disabled",
and confirm with "OK" .
Confirm with "OK" and press
6.7.3.2 - Excluding Wired Detectors (HSCU2C and HSCU2GC
control panels only)
In case of need, you can disable a wired detector and re-enable it at a later
time . This does not delete it, but prevents it from being used (alarms sent by
these sensors are not tracked even in the Events List) .
01. Select "Exclude" .
02. Select "Exclude wired inputs"
03. Select the detector/s you wish to exclude and set it/them to "Enabled–
Disabled" .
Confirm with "OK" and press
6.7.4 - Periodic message
Caution– When EN50131 is enabled, this function is always active . However,
you can modify the time and frequency .
This enables technical SMS n . 11 (see table 5) on the control panel, at a precise
time of day and set frequency (e .g .: at 20:30, every 24 hours) .
01. Select "Periodic message" .
02. In the next page, touch "Enable" and select "YES"; then confirm with
"OK" .
03. Touch "Time" and specify at which time of day you wish to send the SMS
confirm with "OK" .
04. Specify the minutes, and confirm once more with "OK" .
05. Touch "Frequency" and specify after how many hours you wish to receive
the message, after the last time it was sent (e .g: "12", i .e . after 12 hours;
"24", after 24 hours, etc .) . Confirm with "OK" .
Caution! – After programming the frequency of the periodic message, you
must enable reception of the technical SMS on the respective phone numbers
(see par . 6 .5) .
6.7.5 - Alarm type
Caution– If EN50131 is enabled, the alarm type may only be set to "Siren" .
This allows you to associate to each zone (A, B, C, D, E, F) a specific sound,
selected between the standard siren sound and a voice message to dissuade
intruders, which can be recorded into the outdoors siren .
In this way, when a detector trips the alarm, the siren emits the sound pro-
grammed for the zone to which the detector in question belongs .
01. Select "Alarm type" .
02. In the next page, select a zone and assign the alarm type: "Siren" (tradi-
tional siren sound) or "Voice" (customised voice message recorded in the
outdoors siren . For recording instructions, refer to the respective sheet in
the HSCU2 control panel Installation Manual . Confirm with "OK" .
Press
to return to the settings menu .
6.7.6 - Outputs
6.7.6.1 - Relays (HSCU2C and HSCU2GC only)
The HSCU2C and HSCU2GC control panels have two programmable relay
outputs which act on certain events (see table 8) .
Factory settings: output n . 1 is set to ON-OFF and output n . 2 is set to "Gen-
to return to the settings menu .
to return to the settings menu .