Type 3004
Technical Data
7.
TEChnICAL DATA
7.1.
operating Conditions
permitted temperatures
Ambient temperature:
Permitted air humidity:
Permitted application area:
Protection class:
noTE!
•
Avoid heat sources which may result in the permitted temperature range to be exceeded.
7.2.
Conformity
CE mark compliant with conforms to EMC Directive 2004/108/EEC (only if cables, plugs and sockets have been
connected correctly).
7.3.
Identification
The rotary actuator is fitted with a rating plate which uniquely identifies the device and indicates the most important
technical data.
Do not remove the rating plate from the rotary actuator!
It is essential for identification when installing and servicing the device.
The warranty is void without the rating plate.
-20 °C ... +70 °C
<70%
0 – 2000 m height
IP67 in accordance with EN 60529 with cable bushing ISO 20 or protective
flap
Use only ATEX-approved cable bushings.
The temperature class and safety label of ATEX approval changes from T6 to
T5 for the emergency current model and the 400 V model.
English
15