Technical data
6
TECHNICAL DATA
6.1
Standards and directives
The device complies with the relevant EU harmonisation leg-
islation. In addition, the device also complies with the require-
ments of the laws of the United Kingdom.
The harmonised standards that have been applied for the con-
formity assessment procedure are listed in the current version of
the EU Declaration of Conformity/UK Declaration of Conformity.
According to Pressure Equipment Directive the following operating
conditions must be observed:
Maximum pressure for compressible fluids
Line connection
of Group 1 (hazardous gases and vapors
orifice
according to Art. 3 No. 1.3 Letter a first
DN65
6.2
Type label
WARNING!
Risk of injury from high pressure!
Important device-specific technical specifications are indicated
on the type label.
▶ Observe permitted pressure range on the type label of the
device.
Type 2101
dash)
15 bar
Body material
1)
Sealing material
1)
Orifice of the body /
actuator size
Control function
(CF)
Type
2101 A 32M PTFE VA
Tmed -10°C - +185°C
Made in Germany
Flow 1
00218445
ID number of
Flow direction
the device
Permitted medium
Main dimensions
temperature
port connection
Fig. 1:
Type label - example
6.3
Conversion of actuator sizes
Actuator size
Designation
[mm]
50
D
70
M
90
N
130
P
Tab. 1:
Conversion of actuator sizes
english
Permitted
medium pressure
Permitted
pilot pressure
CE identification
Identification for
food contact
Pilot 4,8-10bar
Pmed 8,5bar
2 Da=42,4
s=2,0 Kv 19,5 W11MS
Date of manu-
facture (encoded)
Flow capacity in standard
production conditions
Outer diameter
Scale drawing
A [mm]
64,5
91
120
159
7