Risk of burns/fire due to hot device surface if device operated
continuously!
▶ Do not touch the device with your bare hands.
▶ Keep the device away from highly flammable substances and
media.
Ensure the following the prevent injuries:
▶ Secure the system/device against unintentional activation.
▶ Feed only those media, which are listed in the chapter "Tech-
nical data" as flow media, into the medium ports.
▶ Do not make any internal or external changes to the Type 2060
INOX device.
▶ Only trained technicians carry out installation and mainte-
nance work.
▶ Following an interruption in the power supply, ensure that
the process is restarted in a controlled manner.
▶ Do not use in areas susceptible to vibrations.
▶ Do not mechanically load the device.
▶ Observe general engineering standards and rules.
5
TECHNICAL DATA
5.1
Conformity
The angle seat valve Type 2060 INOX conforms to the EU directives
as per the EU Declaration of Conformity.
5.2
Standards
The applied standards as used to verify compliance with the
EU Directives can be found in the EU type examination certificate
and/or the EU Declaration of Conformity.
4
5.3
General technical data
Control functions: A (CFA)/B (CFB)
CFA: Closed by spring force in rest position.
CFB: Opened by spring force in rest position.
For materials and ports: see data sheet
Installation position: any, preferably actuator facing up
5.4
Inscription on the type label
Control function (CF)
For derating, please refer to the
Identification number of device
Permitted ambient temperature
Permissible medium pressure, permissible
English
Type 2060 INOX
Quickstart
Type
Flow direction
Manufacture code
CE marking (if applicable)
operating instructions,
pilot pressure
Seal material
Flow
coefficient