Warranty terms

This document does not offer any form of guaranties. Please
refer to our general terms and conditions of business.
The guarantee is only valid if the device has been used cor-
rectly in accordance with the specified operating conditions
and the directions in these instructions.
Failure to observe these instructions, altering the exterior of
the device as well as tampering with the device in any way
releases us from all liability and invalidates the warranty for
the devices and accessories.
NOTE!
The warranty only covers the fault-free operation of
the device and the approved accessories.
We accept no liability for consequential damage of
any kind which may arise from the failure or incor-
rect operation of the device.
8
Type plate (Example)
Housing material
Sealing material
Nominal size
Circuit function
Type
Id. No.
Voltage - Frequency - Power
Nominal pressure
10

Technical data

• Body materials:
Brass, Stainless steel
• Fluids:
Neutral gases and liquids,
Technical vacuum
• Circuit function
2/2-way valve:
A (NC)
• Ambient temperature:
• Medium temperature depending
on coil and gasket material
Polyamide coil/FKM:
Epoxy coil/FKM:
Epoxy coil/EPDM:
Epoxy coil/PTFE/graphite:
• Protection class:
Subject to change without notice!
NOTE!
Observe voltage (tolerance of ±10 %), current
type and pressure according to the type plate of
the device.

Installation instructions

WARNING!
Risk of injury during installation the valve in the
system!
Disconnect the voltage!
Disconnect pressure to the system!
Clean the pipelines.
If the medium is contaminated, install a filter
(mesh width 0.2 to 0.4 mm).
Install in any position.
Preferred direction; actuator on top.
Use suitable tools for screwing on!
Use proper tools for connecting the piping!
Hold the valve by its' housing!
Do not use the coil as a lever
Seal the pipe connection with PTFE tape. The tape
must not get inside the valve!
NOTE!
Observe the direction of flow!
Direction of flow: from 1
2 (A)
1 (P)
max. +55 °C
-10 to +100 °C
-10 to +120 °C
-30 to +120 °C
max. +180 °C
IP65 with device socket
2 (from P
A)
9