9. FAULT FINDING

Before attempting to diagnose any fault, make sure that the fuses have been removed or the mains switch has been
switched off. It must be ensured that the power supply cannot be accidentally switched on. All rotating parts must
have stopped moving.
All regulations applying to pumps installed in potentially explosive environments must be observed. It must be
ensured that no work is carried out in potentially explosive atmosphere.
INCONVENIENTS
Failure in
electric pump.
Electric pump starting with thermal
protection intervention winding.
Electric pump drawing more power
than value of plate.
Insufficient performances.
ENGLISH
PROBABE CAUSES
Lack of current to the motor.
Insufficient voltage.
Thermal protection activated.
No signal from electrodes for level control.
One phase interruption (three-phase motors).
Clogged impeller.
Motor failure.
Voltage different from plate.
Wrong rotation direction.
Three-phase motor: phase interruption.
Three-phase motor: Low rating.
Short-circuit; earth leakage in electric cables or
motor.
Too high temperature of pumped liquid.
Pumped liquid too dense.
Dry running of the electropump.
Defective thermal relay.
Overload due to pump clogged.
Pumped liquid too dense or viscious.
Overload due to obstruction.
Wrong rotation direction.
The pump is operating outside the allowed
working range.
Suction, impeller, valve ordelivery pipeline
clogged.
Weared pump or impeller.
Errato senso di rotazione.
Air or gas in the pumped liquid.
Presence of air in the pump.
29
REMEDIES
Check electric network, supply cables,
connections and fuses.
Check the value (see chapter 10
"Technical Data").
Wait for motor cooling,
relay and check ratin starting.
Wait for level reset, check efficiency of
level control relay and relevant electrodes.
Reset connections.
Remove obstruction, wash and clean
(contact
the
Assistance
necessary).
contact the Assistance Service.
Measure the voltage between two phases
of the motor. Tolerance: - 10 %/+ 6 %.
Restore the correct voltage.
Invert two of the three phases (see par.
7.2: "Direction of rotation")
Reset connections.
Adjust rating of relay value.
Individuate interruption and repair (contact
the Assistance Service if necessary).
Check whether the right type of pump has
been selected.
Dilute liquid. Check whether the right type
of pump has been selected.
Check the level of liquid in the sinkhole
and the level control instruments.
Replace it.
Remove obstruction and clean (contact
Assistance Service if necessary).
Dilute liquid. Check whether the right
pump has been selected.
Remove
obstruction
and
extraneous bodies.
Invert two of the three phases (see par.
7.2: "Direction of rotation").
Check the work point of the pump and, if
necessary, increase the delivery pressure.
Clean carefully.
Replace or repair.
Invert two of the three phases (see par.
7.2: "Direction of rotation").
Increase dimensions of pit or collecting
tank and foresee degasing devices.
Vent
the
pump.
(see
paragraph).
reset thermal
Service
if
clean
of
installation

Publicité