Télécharger Imprimer la page

Master DC 61 Manuel D'utilisation Et De Maintenance page 10

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
►►10. PREVENTIVE MAINTENANCE SCHEDULE
WARNING: BEFOR INITIATING ANY REPAIR OR MAINTENANCE PROCEDURE UNPLUG THE FEEDER CA-
BLE AND MAKE SURE THAT THE HEATER IS COOLED DOWN.
IF THE HEATER IS USED IN PARTICULARLY DUSTY ENVIRONMENTS, MAINTENANCE AND CLEANING
COMPONENT
Fuel tank
Clean every 150-200 hours of operation or when
necessary
Nozzle
Clean or replace once per season or when ne-
cessary
Photocell
Clean once per season or when necessary
Fuel filter
Clean or replace twice per season or when ne-
cessary
Ignition device
Clean or replace every 1.000 hours of operation,
or when necessary
Fan blades
Clean when necessary
►►11. PROBLEM IDENTIFICATION
PROBLEM
Heater doesn't run
1. Heater blocked
2. The power switch is in the "OFF" (0) position
3. No power
4. Feeder cable unplugged
5. Blocked control card
6. Wrong thermostat setting
7. Temperature sensor override
8. Fuse damaged
Motor/pump runs
1. No fuel
but the flame does
not start
2. Ignition device is dirty
3. Fuel filter is dirty
4. Nozzle is dirty
5. Photocell is dirty, damaged or installed
improperly
6. Foreign substances present in the tank
7. Electrodes are used up or placed at an
improper distance
Fan blocked or
1. Engine damaged
spins too slowly
MUST BE CARRIED OUT MORE FREQUENTLY.
MAINTENANCE FREQUENCY
POSSIBLE CAUSE
MAINTENANCE PROCEDURE
Empty and rinse with fresh fuel
Contact the technical service center
Contact the technical service center
Clean the fuel filter with clean fuel
Contact the technical service center
Contact the technical service center
POSSIBLE SOLUTION
1. Restart the heater
2. Turn the switch "ON" (|)
3A. Plug the feeder cable properly into the socket
3B. Check the power supply network
3C. Contact the technical service center
3D. Flat battery
4. Contact the technical service center
5A. Restart the heater
5B. Identify the display error
5C. Contact the technical service center
6. Calibrate the thermostat by setting it higher than
ambient temperature
7A. Wait at least ten minutes then try to run ignition
again
7B. Contact the technical service center
8. Contact the technical service center
1. Turn off the heater, refill the fuel tank then restart
the heater
2. Contact the technical service center
3. Clean the filter using clean fuel
4. Contact the technical service center
5. Contact the technical service center
6. Empty and refill the fuel tank with clean fuel
7. Contact the technical service center
1. Contact the technical service center
en