Dexxo Pro io
> Remote lighting (Fig. 38)
Class 2 (double insulation) light units that are connected do not require an earth
connection.
Various types of lighting can be connected without exceeding a total power
consumption of 500 W.
7 - SETUP
7.1 Meanings of the various parameters
(Boldface text = default values)
Operating mode
Values
0 : sequential
1: automatic closure
Comments
Automatic closure mode operation is only possible if
photoelectric cells are fitted, i.e. P2=1 or P2=2.
In automatic closure mode, the door is automatically closed
after the end of the time delay set with setting "t0".
Orange warning light
Values
0: without advance warning
1: with 2 s advance warning
Comments
If the garage opens onto a public road, always select with
advance warning: P1=1
Safety input
Values
0: no safety mechanism
1: safety mechanism with self test
2: safety mechanism without self test
Comments
If value 0 is selected, the safety input is not taken into
account.
If value 1 is selected, the system's self test is run at the start
of every operating cycle.
If value 2 is selected, the safety system runs without a self
test: it is essential to test its proper operation every six
months.
Obstacle detection
sensitivity
Values
0: very low sensitivity
1: low sensitivity
2: standard
3: high sensitivity
If this parameter P3 is modified, the installer must check that the
obstacle detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Partial opening cycle
Values
0 : not valid
1 : valid
Comments
If the partial opening cycle is validated (value 1):
Pressing the button programmed for partial opening causes
partial opening; pressing the button programmed for full
opening causes full opening.
When this parameter is activated, pressing a
previously programmed remote control button will
partially open the garage door; an additional command
must then be performed so that the button fully opens
the gate again (refer to "Programming Keygo io remote
controls for full and partial opening operation")..
9
WARNING
Closing speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
By default, 6: approx. 12 cm/s
Comments
If spurious detection of obstacles occurs when this
parameter is modified, end limit setting and auto-
programming will need to be repeated.
If this parameter P5 is modified, the installer must check that the
obstacle detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Partially open position
Values
Storing the position as illustrated in Fig. 40.
Docking zone when closing (reduction of speed)
Values
0: short (over approx. the last 5 centimetres)
1: standard (over approx. the last 30 centimetres)
2: long (over approx. the last 50 centimetres)
Comments
If spurious detection of obstacles occurs when this
parameter is modified, end limit setting and auto-
programming will need to be repeated.
If this parameter P7 is modified, the installer must check that the
obstacle detection complies with annex A of the standard EN 12 453.
Non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Opening speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
Comments
If spurious detection of obstacles occurs when this
parameter is modified, end limit setting and auto-
programming will need to be repeated.
Choice of operating direction (type of door)
Values
0: direction 1: all types of doors except swinging doors
1: direction 2: swinging doors
Comments
If this parameter is modified, end limit setting and auto-
programming will need to be repeated.
Safety action prior to opening (safety ADMAP)
Values
0: no effect
1: movement rejected
Comments
If value 1 is selected, triggering the safety input will inhibit
door opening.
Safety action during closure
Values
1: stop
2: stop + partial re-opening
3: fully reopen
Comments
Value 1 is not allowed when using a sensor bar on the
safety input.
Obstacle detection action during closure
Values
2: stop + partial re-opening
3: fully reopen
Copyright © 2015 SOMFY ACTIVITES SA. All rights reserved
WARNING
WARNING