Setup; Meanings Of The Various Parameters - SOMFY Dexxo Pro RTS Manuel D'installation

Masquer les pouces Voir aussi pour Dexxo Pro RTS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Dexxo Pro RTS

7 - setuP

7.1 Meanings of the various parameters

(Boldface text = default values)
total operating mode
Values
0: sequential
1: sequential + timed close
2: automatic closure
3: automatic closure by cells
P0 = 0: each press on the remote control causes the
Comments
motor to move (initial position: door closed) as per the
following cycle: open, stop, close, stop, open...
P0 = 1: Automatic closure mode operation is only possible if
photoelectric cells are fitted, i.e. P2=1 or P2=2.
In sequential mode with automatic timed close:
- the door is closed automatically after the timed delay
programmed in parameter "t0",
- pressing a button on the remote control interrupts the
movement taking place and the timed close.
P0 = 2: Automatic closure mode operation is only possible if
photoelectric cells are fitted, i.e. P2=1 or P2=2.
In automatic closure mode:
- the door is closed automatically after the timed delay
programmed in parameter "t0",
- pressing a button on the remote control during opening
has no effect,
- pressing a button on the remote control during closing
causes it to reopen,
- pressing a button on the remote control during the timed
close restarts the timed delay.
P0 = 3: Automatic closure mode operation is only possible if
photoelectric cells are fitted, i.e. P2=1 or P2=2.
After the door is opened, movement in front of the cells (safe
closure) will close the door after a short timed delay (fixed at 5
seconds).
If there is no movement in front of the cells, the door will close
automatically after the timed close programmed in parameter
"t0".
If there is an obstacle in the cells' detection zone, the door will
not close. It will close once the obstacle is removed.
orange warning light
0: without advance warning
Values
1: with 2 s advance warning
Comments
If the garage opens onto a public road, always select with
advance warning: P1=1
safety input
0: no safety mechanism
Values
1: safety mechanism with self test
2: safety mechanism without self test
Comments
If value 0 is selected, the safety input is not taken into
account.
If value 1 is selected, the system's self test is run at the
start of every operating cycle.
If value 2 is selected, the safety system runs without a self
test: it is essential to test its proper operation every six
months.
obstacle detection
sensitivity
Values
0: very low sensitivity
1: low sensitivity
2: standard
3: high sensitivity
If this parameter P3 is modified, the installer must check that the
obstacle detection complies with annex A of the standard en 12 453.
non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Copyright © 2015 Somfy SAS. All rights reserved
WArnIng
Partial operating mode
Values
0: sequential
1: sequential + timed close
Comments
P4 = 0 : Each press on the remote control causes the motor
to move (initial position: door closed) as per the following
cycle: open, stop, close, stop, open...
P4 = 1: Automatic closure mode operation is only possible if
photoelectric cells are fitted, i.e. P2=1 or P2=2.
In sequential mode with automatic timed close:
- the door is closed automatically after the timed delay
programmed in parameter "t2",
- pressing a button on the remote control interrupts the
movement taking place and the timed close.
Closing speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
By default, 6: approx. 12 cm/s
Comments
If spurious detection of obstacles occurs when this
parameter is modified, end limit setting and auto-
programming will have to be carried out again.
If this parameter P5 is modified, the installer must check that the
obstacle detection complies with annex A of the standard en 12 453.
non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
Partially open position
Values
Storing the position as illustrated in Fig. 32.
Closure approach speed
Values
0: no slowdown
1: short soft stop
2: long soft stop
Comments
P7=0: the door does not slow before closure.
P7=1: the door speed slows 20 centimetres before closure.
P7=2: the door speed slows 50 centimetres before closure.
If spurious detection of obstacles occurs when this
parameter is modified, end limit setting and auto-
programming will have to be carried out again.
If this parameter P7 is modified, the installer must check that the
obstacle detection complies with annex A of the standard en 12 453.
non-observance of this instruction can result in serious injury to
persons, e.g. when trapped by a door.
opening speed
Values
0: slowest speed: approx. 3.5 cm/s
to
9: fastest speed: approx. 18 cm/s
Choice of operating direction (type of door)
Values
0: direction 1: all types of doors except swinging doors
1: direction 2: swinging doors
Comments
If this setting requires modification the end limit setting must
be repeated along with self-learning.
WArnIng
WArnIng
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dexxo pro 800 rtsDexxo pro 1000 rts

Table des Matières