en
● For safety reasons, we recommend installing a residual current circuit breaker (RCB).
● Observe the data on the type plate when making the electrical connection!
● Integrate the appliance into the equipotential bonding system. Its effectiveness must be checked
in accordance with VDE 0190.
● Securely connect the mains connection cable at the customer's premises.
10.4
Opening the bottom front panel
10.5
Connect the appliance to the U-channel
Screw
U-washer
Panel
U-washer
48 / 76
Undo screws
Screw
Required for the electrical connection.
Front panels must only be removed by authorized
customer service or electrician!
Opening the bottom front panel
. Release the screws below the front panel.
. Remove and place down the front panel.
Information, routing mains connection
line
● Option of routing the cable through the rear
wall or from below.
● Do not route the electric cable along hot sur
faces or sharp edges!
Remove the covers
. Open the "top front cover" (Chapter 10.4).
. Depending on the type of appliance: Remove
"bottom front cover".
. Remove the screws.
. Remove the covers.