Fault
The appliance is
switched on but does
not heat up.
Indicator for mainte
nance interval:
Indicator changes be
tween "H20" and "0"
Fault report:
E01 and E03
Fault report:
E02 and E04
Fault report:
E05 and E06
Fault report:
E07 and E08
Tilting is not possible.
Fault report:
E15
Fault report:
E16
Fault report:
E20 to E36
Characters appear on
the display that do not
conform to the indica
tion of time and tem
perature.
If the fault cannot be rectified:
. Switch off the unit.
. Switch on the mains switch on the front of the appliance.
. Do not open the housing.
. Contact customer service.
Possible cause
The bratt pan is not
fully lowered.
Appliance requires
maintenance
Short circuit in the tem
perature sensor.
Interruption of the tem
perature sensor.
The safety temperature
limiter has tripped.
Heating element or
contactor defective.
Maximum temperature
exceeded.
Lid not fully open.
The safety temperature
limiter has tripped.
Fault in the control
You have inadvertently
selected the setup
menu that is only in
tended for service
tasks by customer ser
vice.
Remedy
Fully lower the bratt pan.
Operation can continue.
Press an arbitrary key. The maintenance
message has been postponed by four
hours.
Contact customer service for maintenance.
Information about the maintenance interval,
refer to Page 41, Chapter 5.9
Turn the appliance off and on. Contact the
customer service if the fault recurs.
Turn the appliance off and on. Contact the
customer service if the fault recurs.
Turn the appliance off and on. Contact the
customer service if the fault recurs.
The bratt pan has overheated.
Switch off fault message -> Switch appli
ance off and on.
Fully open the lid.
Contact customer service.
Turn the appliance off and on. Contact the
customer service if the fault recurs.
Turn the appliance off and on.
en
45 / 76