Grid voltage limits
outer limit value
Grid frequency limits:
Q-mode:
AC power limit includ-
ing SoftStart indicator
and/or AC grid fre-
quency derating:
AC voltage derating:

Version

Displays the version and serial numbers of the PC boards in the inverter (e.g. for service
purposes)
Display area
UMax - upper outer grid voltage in V (volts)
TTMax - Trip Time Max - trip time for exceeding the upper
outer grid voltage limit value in cyl*
UMin - lower outer grid voltage in V (volts)
TTMin - Trip Time Min - trip time for falling below the lower
outer grid voltage limit value in cyl*
*cyl = grid periods (cycles); 1 cyl corresponds to 20 ms at 50
Hz or 16.66 ms at 60 Hz
FILmax - upper inner grid frequency in Hz (Hertz)
FILmin - lower inner grid frequency in Hz (Hertz)
FOLmax - upper outer grid frequency in Hz (Hertz)
FOLmin - lower outer grid frequency in Hz (Hertz)
Indicates which reactive power setting is currently active on
the inverter (e.g. OFF, Q / P, etc.)
Max P AC - maximum output power, which can be changed
using the "Manual Power Reduction" function
GPIS - Gradual Power Incrementation at Startup - indicates
(%/sec) whether the SoftStart function is active on the
inverter
GFDPRe - Grid Frequency Dependent Power Reduction
enable limit - indicates the set grid frequency in Hz (Hertz)
from when power derating takes place
GFDPRv - Grid Frequency Dependent Power Reduction
derating gradient - indicates the set grid frequency in %/Hz,
how strong power derating is
GVDPRe - Grid Voltage Depending Power Reduction enable
limit - threshold value in V from which voltage-dependent
power derating starts
GVDPRv - Grid Voltage Depending Power Reduction derat-
ing gradient - derating gradient %/V with which the power is
reduced
Message - indicates whether the dispatch of an info message
via Fronius Solar Net is active
Display / Display Software / Integrity Checksum / Memory
Card / Memory Card #1 / Power Stage / Power Stage Soft-
ware / EMI Filter / Power Stage #3 / Power Stage #4