Les langues disponibles

Les langues disponibles

Values displayed in the LOG menu item:
(for today, during the current calendar year and since the inverter was started for the
first time)
AC Energy Yield (kWh / MWh)
Energy fed into the grid during the period in question
There may be discrepancies with values displayed on other measuring instruments
because of differences in measuring methods. As far as the billing of the energy fed in
is concerned, the only binding display values are those produced by the calibrated
measuring device provided by the electricity supply company.
AC Max. Output Power (W)
Largest amount of power fed into the grid during the period in question
Earnings
Amount of money earned during the period in question (currency can be selected in
the Setup menu)
Like the energy supplied figure, the yield figure may also exhibit discrepancies with
other measured values.
The 'Setup Menu' section explains how to select a currency and charge rate.
The factory setting depends on the respective country setup.
CO2 savings (g / kg)
CO
emissions saved during the period in question
2
The value for CO
savings depends on the power station facilities and corresponds to
2
the CO
emissions that would be released when generating the same amount of
2
energy. The factory setting is 0.53 kg / kWh (source: DGS – Deutsche Gesellschaft für
Sonnenenergie e.V. (German Society for Solar Energy).
AC Max. Voltage L-N (V)
Highest voltage measured between the conductor and neutral conductor during the
period in question
PV Array Max. Voltage (V)
Highest solar module voltage measured during the period in question
Operating Hours
Length of time the inverter has been working (HH:MM).
IMPORTANT! A prerequisite for the correct display of day and year values is that the
time is set correctly.
21