Technical data
FRONIUS PRIMO
Input data
MPP voltage range
Max. input voltage
at 1,000 W/m²/ 14 °C in an open circuit
Max. input current (MPPT 1 / MPPT 2)
Max. short circuit current of the solar modules
4)
Max. feedback current
Output data
Nominal output power (P
Max. output power
Nominal grid voltage
Min. grid voltage
Max. grid voltage
Max. output current
Nominal frequency
Total harmonic distortion
cos phi power factor
Max. permissible mains impedance Z
6)
Power-up current pulse
Max. output fault current per period
General data
Maximum efficiency
European efficiency
Overnight self-consumption
Cooling
Degree of protection
Dimensions h x w x d
Weight
Permissible ambient temperature
Permitted humidity
EMC device class
Overvoltage category DC / AC
Inverter topology
)
nom
3)
on PCC
max
and duration
3.0-1
3.5-1
200 - 800 V
1000 V
12.0 A
18.0 A
18.0 A
3000 W
3500 W
3000 W
3500 W
1 ~ NPE 220 / 230 / 240 V
150 V
270 V
13.7 A
16.0 A
50 / 60 Hz
< 5 %
0.85 - 1 ind./cap.
None
38 A / 172 ms
98.0 %
98.0 %
96.1 %
96.8 %
0.6 W
Controlled forced-air ventilation
IP 65
628 x 428 x 205 mm
21.6 kg
-40 °C - +55°C
0 - 100%
B
2 / 3
non-isolated transformerless
3.6-1
3680 W
3680 W
1)
1)
16.8 A
1)
2)
98.0 %
96.8 %
51