Levelling Of The Appliance; Electrical Connection - Palazzetti ECOFIRE TWIGGY Notice D'installation Et D'entretien

Masquer les pouces Voir aussi pour ECOFIRE TWIGGY:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

6.3.1 Hot air outlet selector
Using the Allen key it is possible to choose the
hot air outlet:
• upper (Fig. 26) ;
• upper and rear (Fig. 27).
004771070 - 17/11/2020
ITALIANO
ENGLISH
Fig. 26
Fig. 27
DEUTSCH

6.4 Levelling of the appliance

The appliance must be levelled, with the aid of a
spirit level, by acting on the adjustment feet (Fig.
28).
A = Spirit level.

6.5 Electrical connection

Simply connect the appliance to the electrical
system using the supplied plug (Fig. 29).
The electrical connection (plug) must be easily
accessible after appliance installation as well.
If the power supply cable is damaged
it must be replaced by the technical
assistance service or a qualified techni-
cian in order to prevent any risk.
It is mandatory that the system is
equipped with an earth connection
and a differential switch in compliance
with the laws in force.
FRANÇAIS
ESPAÑOL
Fig. 28
Fig. 29
51

Publicité

Table des Matières
loading

Table des Matières