5.1.5 Water connection
•
The potable water connection must be positioned in the vicinity of the device.
•
During connection to the new system drain sufficient amount of water before
connecting the device to the water network to prevent penetration of impurities to
the magnetic valves.
•
Connect included hose at 90° to the device connect ion pipe (3/4"). Connection pipe
location: under the device, on the right side, at the back. Another hose end should be
connected to cold water network with use of cut-off valve.
WARNING!
Water pressure should be max. 3 bar.
In case of higher pressure use the pressure reducer (page 56).
•
To assure failure-free operation of the device and prevent scale deposits in the
chamber use potable water of hardness of do 7° d.H.
WARNING!
In case of water hardness above 7° d.H it is requir ed to install
appropriate water softening system.
5.1.6 Connecting to the drain
•
In the water drain tank in front of the device
there is the drain hose (internal diameter 10
mm) used for removing excess of liquid from
the tank and installed at the back, under the
device (A – fig. on the right).
To connect to appropriate drain system
properly extend the included hose.
•
Included drain pipe (B) should be fixed to the
drain hole under the device to assure liquid flow
from the chamber. Drain pipe
must be connected with use of appropriate hose
(Ø 22 mm) and led to the drain system.
A
B
- 63 -