Comply with the maximum ambient temperature
When using ATEX encoders, observe the limited ambient
temperature of -20°C ... +60°C [-4°F ... +140°F].
Temperature range of connectable components
When choosing then accessories, in particular the connect-
ors, observe the maximum temperature of these components.
8.2.2 Temperature / Speed Curves
Hollow shaft encoder
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 04
NOTICE
NOTICE
9007199359642891
Solid shaft encoder
8.3 Declaration of Conformity
All declarations of conformity and certificates relating to the
product can be downloaded from our homepage:
www.kuebler.com/docufinder
9007199371112587
.
EN - 63