End Of Programming - Kübler CODIX 541 Notice De Mise En Service

Masquer les pouces Voir aussi pour CODIX 541:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.4 Multiplying factor
4.5 Dividing factor
4.6 Decimal point
4.7 SET/RESET Mode
5
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
manual reset via the red
SET/RESET key and
electrical reset via the
SET/RESET input
no reset (red SET/RESET
key and SET/RESET input
locked)
only electrical reset via the
SET/RESET input
only manual reset via the
red SET/RESET key
4.8 SET value
For programming the decimal point see 4.6

4.9 End of programming

The device will be set to
the set point by pressing
the red SET/RESET key
or activating the
SET/RESET input.
SET value -199999...
999999 (number of deci-
mal places depends on
the decimal point option)
The programming routine
is repeated once more.
The values set until now
can be checked and mod-
ified.
The programming routine
wil be left and all values
set will be stored as new
parameters.
Afterwards the device is
ready for operation.