UL - Underwriters Laboratories
UL approval
Relevant Standards
Maximum air humidity
Environment
ATEX
Relevant Standards
3.6.2 Approvals
The product meets the following criteria:
• Approval according to UL
• Approval for applications with increased functional safety re-
quirements.
• Compliance with the European Directives:
– EMC Directive 2014/30/EU
– RoHS Directive 2011/65/EU
– Machinery Directive 2006/42/EC
– ATEX Directive 2014/34/EU
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 04
File no. E224618
UL 61010-1
Indoor use, outdoor use pos-
sible, not designed for direct
UV radiation.
93 %, 40°C [104°F]
Dry / Wet
EN 60079-0:2012 / A11:2013
EN 60079-15:2010
EN 60079-28:2015
EN 60079-31:2014
Zone 2/22 (optional, variant)
4 Installation
4.1 Mechanical Installation
ATTENTION
Damage to the device due to transport or storage
Device failure, malfunction, device lifetime reduction.
• Check the packaging and the device for possible damages.
• In the event of visible damages, do not use the device and
do not put it into operation.
• Do not install the device after falling or being dropped.
• Send damaged devices back to the manufacturer with a
completed returns form (RMA), see chapter Contact [} 64].
4.1.1 General Information for the Mounting of
Encoders
ATTENTION
Do not disassemble or open the device
The function of the measuring system might be lost partly or
entirely.
• Do not open or disassemble the measuring system. Other-
wise, the warranty will be void.
EN - 45