Mains rated voltage 250 V AC
Rated current 2.5 A
Rated surge voltage 2.5 kV
Connection socket (outer view of the pump connection)
Cable assignment
Pin
Cable colour
1
Brown
2
Yellow/green
3
Blue
Connect cable:
Check the presence and integrity of the seal on the connector before installation.
Connect the cable plug to the mains power socket (Fig. I, Item 13) until it snaps into place.
Ensure that the connecting cable does not contact either the pipes or the pump.
7.2.3
Signal properties
CAUTION
Risk of material damage!
The connection of mains voltage (230 V AC) to the communication pins (iPWM/LIN) will des-
troy the product.
Exclusively connect the power supply to 230 V (phase to neutral conductor)!
PWM and iPWM
Signal frequency: 90 Hz – 5000 Hz (1000 Hz nominal value)
Signal amplitude: Min. 4 V at 3.5 mA to 24.5 V for 10 mA, absorbed by the pump interface
Signal polarity: yes
0 ... 10 V signal
Electric strength 30 V DC/24 V AC
Input resistance of the voltage input > 10 kΩ
LIN bus
Bus speed: 19200 bit/s