Disposal and Recycling
The air conditioning system must be disposed of only
by experts in accordance with the administrative reg-
ulations of the respective country in which it is used�
National regulations and laws must be observed�
USA:
Clean Air Act, 42 U�S� Code § 7671g, 40 CFR Part 82
Subpart F
Canada:
Environmental Code of Practice for the Elimination of
Fluorocarbon Emissions from Refrigeration and Air Con-
ditioning Systems�
The remote control and the batteries must not be
disposed of in domestic waste, but rather must be
recycled separately via a collection point� You then also
make your contribution to reuse and recycling�
40090-00130 · 01 · 11/2023
12
Technical Data
Established in line with AHRI Standard 210/240�
Designation
Cooling capacity
equivalent
Heating capacity
equivalent
Electrical rating
Compressor
Rated Load
Compressor
Locked Rotor
Fan Motor
Rated Load
Fan Motor
Locked Rotor
Refrigerant
Minimum wire
Size1 copper
AC Circuit protection
installer supplied2
Limits of use
Max air conditioner
incline in operation
Weight, plus
installation material
Adjustable tempera-
ture range
Protection type
Generator size
3
For wire length over 24 ft�, consult the National Electrical Code for
1
proper sizing�
2 Circuit Protection: Time delay fuse or circuit breaker required�
See "Operation with generator or power inverter" on page 12
3
An interior air sensor prevents the compressor from op-
erating at temperatures of less than 61 °F (16 °C) during
cooling�
An anti-freeze sensor prevents non-permitted ice forma-
tion on the evaporator coil�
A temperature switch prevents excessive current and
temperature at the compressor�
Truma Gerätetechnik reserves the right to make
technical changes!
Disposal and Recycling
Saphir
7000 BTU / h
6500 BTU / h
120 VAC, 60 Hz ± 5 %
single phase
6�5 A
38 A
1�1 / 1�16 A
(indoor / outdoor)
0,18 / 019 HP
(indoor / outdoor)
R-410A
16�9 oz (480 g)
3 x AWG 12 / 3 x 3�3 mm2
20 Amp
39 – 113 °F
(4°C – 45 °C)
8 % (4�5°)
54�5 lbs (24�7 kg)
62 - 88 °F
16 - 31 °C
IPX5
EN