Télécharger Imprimer la page

Truma Saphir Mode D'emploi page 11

Publicité

Saphir
5
Initial start-up
The following section describes the initial start-up
with Saphir remote control� For CP plus or third-
party control unit, please refer to the operating
instructions of the corresponding control unit�
Before switching on, ensure that the vehicle is sup-
plied with 120 V AC / 60 Hz protected with an 20 A
circuit breaker�
The remote control must always be pointed at the infra-
red receiver in order to perform the individual switching
commands�
Before switching on for the first time, the remote con-
trol must be paired with the IR receiver�
Insert batteries (pay attention to polarity)
Setup symbol flashes
(if symbol does not flash, perform reset)
Point the remote control at at the IR receiver
Press the setup button and hold down
When the green LED in IR receiver flashes, release
the button to pair the remote control with the
IR receiver
The setup symbol goes off and the air conditioning sys-
tem starts the circulated air mode at low fan level and
with no timer set�
40090-00130 · 01 · 11/2023
6
Operation
6.1
Cooling mode
The air conditioning system ensures cool air inside the
vehicle when operated in cooling mode� The circulated
air fan continues to run in order to provide ventilation�
The air is dehumidified during cooling� If the air
humidity in the vehicle is extremely high at the be-
ginning of the cooling procedure, moisture can build
up on the outside of the air ducts� The doors and
windows should therefore be kept closed and the
highest fan level selected�
6.2
Heating mode (reverse cycle mode)
Heating mode is used when a room temperature above
outside temperature is desired� Saphir heats up the
room air using reverse cycle mode� The circulated air
fan continues to run in order to provide ventilation� If
the room temperature drops below the temperature
setting, the compressor will automatically start�
Heating at an outside temperature of less than
39 °F (4 °C) is not recommended because heating
performance falls considerably� Between 39 °F (4 °C)
and 45 °F (7 °C), the device operates at the "low"
fan level and switches briefly to defrosting processes
(for several minutes)� At above 45 °F (7 °C), there are
no restrictions on heating mode� As soon as 54 °F
(12 °C) is reached, the air conditioning system auto-
matically switches to the fan setting selected on the
remote control�
In order to achieve interior heating that is as effec-
tive as possible at low temperatures, the air condi-
tioning system operates at the "low" level at room
temperatures of less than 54 °F (12 °C)� As soon as
54 °F (12 °C) is reached, the air conditioning system
automatically switches to the fan setting selected on
the remote control�
6.3
Circulated air mode
Circulated air mode only circulates the indoor air with-
out heating or cooling it�
6.4
Automatic mode
The automatic mode automatically controls the room
temperature by automatically switching between cool-
ing and heating mode� Automatic mode is used when
the room temperature can be above or below outside
temperature during operation�
6.5
ACC mode
The ACC mode automatically controls the room tem-
perature together with the Truma Saphir air condi-
tioning system and a Truma Combi / Truma VarioHeat
heater� It is referred to as AUTO mode in the CP plus
menu� In AUTO mode, the air conditioning system will
not be operated in reverse cycle mode (heating)�
Initial start-up
EN
11

Publicité

loading