Charging is completed when the „Charge LED" (8) at the charger remains lit. The flight battery can now be discon-
nected and the charger can be removed from the direct current source.
Note: Automatic charging will not start with a rechargeable battery voltage below 0.7 V. Charging will only start if the
rechargeable battery voltage of a cell is less than 4.18 V.
For photo-technical reasons, figure 4 shows the charging cable of the plug-in mains adapter in the wound-up state.
Before first use, the cable retainer should be opened and the cable unwound.
Important!
Never leave the balancer charger and rechargeable battery unattended when charging. Observe the
charging time and check for excessive heating of the balancer charger and the rechargeable battery in
between.
The charging time with the rechargeable battery empty is approx. 1.5 hours. If the „Charge-LED" (8) at the
balancer charger is still flashing after this time, interrupt charging and find the cause at the rechargeable
battery and/or the balancer charger.
Attention!
The left charging socket at the balancer charger (see figure 4, item 9) serves to charge a 3-cell LiPo
rechargeable battery that is charge according to the same chart as described above.
Never charge a 2-cell and a 3-cell rechargeable battery together at the balancer charger! Only connect a
single rechargeable battery!